Heraeus Vötsch
Model: VCS 7018-5
Climatic Test Chamber with Humidity, Water-cooled
Test Chamber Dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Overall Dimensions: Width 870 mm x Depth 1280 mm x Height 1775 mm
Technical Data for Temperature Testing:
Temperature Range: -70°C to +180°C
time deviation: ± 0.1 to ± 0.5 K
spatial deviation: ± 0.5 to ± 2.0 K
Temperature Gradient: 1 to 4 K
Temperature Change Rate according to IEC 60068-3-5
Heating: 7.5 K/min.
Cooling: 7.5 K/min.
Technical Data for Climatic Testing:
Temperature Range: +10 to +95°C
Humidity Range: 10 to 98% r.h.
Temporal Deviation: ± 0.1 to ± 0.3 K
Spatial Deviation: ± 0.5 to ± 1 K
Temperature Gradient: 1 to 2 K
Humidity Fluctuation (temporal): ± 1 to ± 3% r.h.
Dew Point Range: -3 to +94 °C
Electrical Connection:
Rated Voltage: 3/N/PE AC 400V±10% 50Hz
Rated Power: 10 kW
Rated Current: 21 A
Circuit Protection: 32 A slow-blow, to be provided by customer
Refrigerants: R-404A / R-23
Test Chamber Volume: approx. 190 liters
Weight: approx. 460 kg
Important Safety Information for Buyers!
The following points are carried out on our chambers prior to delivery:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant, if necessary
3. Leak tightness test with certificate
4. After successful inspection, chambers undergo a documented test run.
Condition: used
Scope of delivery: (See photo)
(Technical data subject to change and errors excepted!)
For further questions, please feel free to contact us by phone.
Gkodpjv N Hc Esfx Acuoc
Skelbimas verčiamas automatiškai, todėl jame gali būtų vertimo klaidų.
Model: VCS 7018-5
Climatic Test Chamber with Humidity, Water-cooled
Test Chamber Dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Overall Dimensions: Width 870 mm x Depth 1280 mm x Height 1775 mm
Technical Data for Temperature Testing:
Temperature Range: -70°C to +180°C
time deviation: ± 0.1 to ± 0.5 K
spatial deviation: ± 0.5 to ± 2.0 K
Temperature Gradient: 1 to 4 K
Temperature Change Rate according to IEC 60068-3-5
Heating: 7.5 K/min.
Cooling: 7.5 K/min.
Technical Data for Climatic Testing:
Temperature Range: +10 to +95°C
Humidity Range: 10 to 98% r.h.
Temporal Deviation: ± 0.1 to ± 0.3 K
Spatial Deviation: ± 0.5 to ± 1 K
Temperature Gradient: 1 to 2 K
Humidity Fluctuation (temporal): ± 1 to ± 3% r.h.
Dew Point Range: -3 to +94 °C
Electrical Connection:
Rated Voltage: 3/N/PE AC 400V±10% 50Hz
Rated Power: 10 kW
Rated Current: 21 A
Circuit Protection: 32 A slow-blow, to be provided by customer
Refrigerants: R-404A / R-23
Test Chamber Volume: approx. 190 liters
Weight: approx. 460 kg
Important Safety Information for Buyers!
The following points are carried out on our chambers prior to delivery:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant, if necessary
3. Leak tightness test with certificate
4. After successful inspection, chambers undergo a documented test run.
Condition: used
Scope of delivery: (See photo)
(Technical data subject to change and errors excepted!)
For further questions, please feel free to contact us by phone.
Gkodpjv N Hc Esfx Acuoc
Skelbimas verčiamas automatiškai, todėl jame gali būtų vertimo klaidų.
Tiekėjas
Pastaba: Užsiregistruokite nemokamai arba prisijunkite, kad gautumėte visą informaciją.
Pateikti užklausą
Telefonas & Faksas
+49 2861 ... skelbimai
Jūsų skelbimas sėkmingai pašalintas
Įvyko klaida