Klimato bandymų kamera su drėgmės palaikymuWeiss -72°C bis +180°C
WK3-340/70
Klimato bandymų kamera su drėgmės palaikymu
Weiss -72°C bis +180°C
WK3-340/70
Sąlyga
Naudotas
Vieta
Borken 

Rodyti vaizdus
Rodyti žemėlapį
Duomenys apie mašiną
- Įrenginio aprašas:
- Klimato bandymų kamera su drėgmės palaikymu
- Gamintojas:
- Weiss -72°C bis +180°C
- Modelis:
- WK3-340/70
- Sąlyga:
- labai geros būklės (naudotas)
Kaina ir vieta
- Vieta:
- Einsteinstraße 8a, 46325 Borken, DE
Skambinti
Pasiūlymo informacija
- Sąrašo ID:
- A18791221
- Nuorodos Nr.:
- 24566
- Naujinta paskutinį kartą:
- Data 2025.07.02
Aprašymas
Weiss
Model: WK3-340/70
Weiss Climate Test Chamber, Air-Cooled
Control Unit: "Touch Panel"
All control and operating commands can be executed by simply touching the functional icons on the "Touch Panel" control unit.
Adjustable Feet
To compensate for uneven floors and to ensure adequate ventilation of the machine compartment, the test chamber is equipped with adjustable feet.
Feedthroughs
The test chamber is equipped with feedthroughs on both the right and left sides. These allow measuring cables and test devices to be routed into the test chamber.
Standard feedthroughs installed:
Right (R1): nominal width 125 mm
Left (L1): nominal width 85 mm
Volume: 335 liters
Test Chamber Internal Dimensions:
Height: 750 mm, Width: 580 mm, Depth: 765 mm
External Dimensions:
Height: 1775 mm, Width: 870 mm, Depth: 1600 mm
Specifications for Temperature Tests:
Minimum temperature: –72°C
Maximum temperature: +180°C
Temperature deviation over time: ± 0.1 to ± 0.5 K
Temperature uniformity (spatial): ± 0.5 to ± 1.5 K
Temperature change rate, cooling: 3 K/min
Temperature change rate, heating: 3 K/min
Specifications for Climate Tests:
Temperature range: +10°C to +95°C
Dew point range: -3°C to +94°C
Humidity range: 10 to 98% r.H.
Temperature deviation over time: ± 0.1 to ± 0.3 K
Temperature uniformity (spatial): ± 0.5 to ± 1 K
Humidity deviation over time: ± 1 to ± 3% r.H.
Dkodpfx Asv Sr Hzsf Hsu
Operating Data:
Test chamber lighting: Halogen bulbs 2 x 24V, 50W
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 16 A
Rated power: 4.9 kW
Fuse (on-site): 16 A slow-blow
Refrigerants: R-452A/R23
Weight: approx. 585 kg
For your security as a buyer, please note the following information!
The following points are carried out in advance on our offered chambers:
1. Functional verification and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Modifications and errors in technical data are subject to change!)
We will be happy to answer further questions by phone.
Skelbimas verčiamas automatiškai, todėl jame gali būtų vertimo klaidų.
Model: WK3-340/70
Weiss Climate Test Chamber, Air-Cooled
Control Unit: "Touch Panel"
All control and operating commands can be executed by simply touching the functional icons on the "Touch Panel" control unit.
Adjustable Feet
To compensate for uneven floors and to ensure adequate ventilation of the machine compartment, the test chamber is equipped with adjustable feet.
Feedthroughs
The test chamber is equipped with feedthroughs on both the right and left sides. These allow measuring cables and test devices to be routed into the test chamber.
Standard feedthroughs installed:
Right (R1): nominal width 125 mm
Left (L1): nominal width 85 mm
Volume: 335 liters
Test Chamber Internal Dimensions:
Height: 750 mm, Width: 580 mm, Depth: 765 mm
External Dimensions:
Height: 1775 mm, Width: 870 mm, Depth: 1600 mm
Specifications for Temperature Tests:
Minimum temperature: –72°C
Maximum temperature: +180°C
Temperature deviation over time: ± 0.1 to ± 0.5 K
Temperature uniformity (spatial): ± 0.5 to ± 1.5 K
Temperature change rate, cooling: 3 K/min
Temperature change rate, heating: 3 K/min
Specifications for Climate Tests:
Temperature range: +10°C to +95°C
Dew point range: -3°C to +94°C
Humidity range: 10 to 98% r.H.
Temperature deviation over time: ± 0.1 to ± 0.3 K
Temperature uniformity (spatial): ± 0.5 to ± 1 K
Humidity deviation over time: ± 1 to ± 3% r.H.
Dkodpfx Asv Sr Hzsf Hsu
Operating Data:
Test chamber lighting: Halogen bulbs 2 x 24V, 50W
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 16 A
Rated power: 4.9 kW
Fuse (on-site): 16 A slow-blow
Refrigerants: R-452A/R23
Weight: approx. 585 kg
For your security as a buyer, please note the following information!
The following points are carried out in advance on our offered chambers:
1. Functional verification and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Modifications and errors in technical data are subject to change!)
We will be happy to answer further questions by phone.
Skelbimas verčiamas automatiškai, todėl jame gali būtų vertimo klaidų.
Tiekėjas
Pastaba: Užsiregistruokite nemokamai arba prisijunkite, kad gautumėte visą informaciją.
Pateikti užklausą
Telefonas & Faksas
+49 2861 ... skelbimai
Jūsų skelbimas sėkmingai pašalintas
Įvyko klaida