Klimato kamera su drėgme 34 litraiWeiss
WKL 34/60 -60°C bis 150°C
Klimato kamera su drėgme 34 litrai
Weiss
WKL 34/60 -60°C bis 150°C
Sąlyga
Naudotas
Vieta
Borken 

Rodyti vaizdus
Rodyti žemėlapį
Duomenys apie mašiną
- Įrenginio aprašas:
- Klimato kamera su drėgme 34 litrai
- Gamintojas:
- Weiss
- Modelis:
- WKL 34/60 -60°C bis 150°C
- Sąlyga:
- labai geros būklės (naudotas)
Kaina ir vieta
- Vieta:
- Einsteinstraße 8a, 46325 Borken, DE
Skambinti
Pasiūlymo informacija
- Sąrašo ID:
- A16211179
- Nuorodos Nr.:
- 24134
- Naujinta paskutinį kartą:
- Data 2024.11.15
Aprašymas
Weiss
Type: WKL 34/60
Weiss climatic chamber, air-cooled
Refrigerant converted to R-452A
-60°C to 150°C
Chamber volume: 34 liters
Feed-throughs in standard configuration installed:
R1 NW 50 mm
L1 NW 120 mm
Internal dimensions: Height 310 mm x Width 324 mm x Depth 300 mm
External dimensions: Height 1740 mm x Width 630 mm x Depth 970 mm
Specifications for temperature tests:
Temperature range: -60 to +150 °C
Temperature deviations under steady-state conditions (according to IEC 60068-3-5):
Temporal fluctuation at center of workspace: ± 0.3 to ± 1 K / ± 1 to ± 2 K
Spatial deviation (temperature gradient): 2 to 4
Temperature change rate (per IEC 60068-3-5):
Heating: 2.5 K/min
Cooling: 3 K/min
Maximum heat compensation: 550 W
Specifications for climatic tests:
Temperature range: +10 to +95 °C
Humidity range: 10 to 98 % r.h.
Temperature and humidity deviations (steady-state, per IEC 60068-3-5):
Temporal temperature fluctuation at center of workspace: ± 0.3 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 (temperature gradient): 1 to 3
Temporal humidity fluctuation at center of workspace: ± 3 to ± 5 % r.H.
Operational data:
Test chamber illumination: Halogen bulb 12V, 20W
Rated voltage: 1/N / PE AC 230 V ± 10% 50 Hz
Rated power: 2.5 kW
Rated current: 11 A
Protection (on-site): 16A slow-blow
Heat emission (air-cooled chamber):
Gjdpfx Aetr Dinocuobu
Maximum heat emission to ambient: 1700 W
Refrigerant: R-452A / R23
Weight: 140 kg
Important safety information for the buyer!
The following points will be completed on our offered chambers prior to delivery:
1. Functional check and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certificate
4. Upon successful completion, the chamber undergoes a documented test run.
Condition: used
Scope of delivery: (see picture)
(Technical data subject to change and error!)
We are happy to answer further questions by phone.
Skelbimas verčiamas automatiškai, todėl jame gali būtų vertimo klaidų.
Type: WKL 34/60
Weiss climatic chamber, air-cooled
Refrigerant converted to R-452A
-60°C to 150°C
Chamber volume: 34 liters
Feed-throughs in standard configuration installed:
R1 NW 50 mm
L1 NW 120 mm
Internal dimensions: Height 310 mm x Width 324 mm x Depth 300 mm
External dimensions: Height 1740 mm x Width 630 mm x Depth 970 mm
Specifications for temperature tests:
Temperature range: -60 to +150 °C
Temperature deviations under steady-state conditions (according to IEC 60068-3-5):
Temporal fluctuation at center of workspace: ± 0.3 to ± 1 K / ± 1 to ± 2 K
Spatial deviation (temperature gradient): 2 to 4
Temperature change rate (per IEC 60068-3-5):
Heating: 2.5 K/min
Cooling: 3 K/min
Maximum heat compensation: 550 W
Specifications for climatic tests:
Temperature range: +10 to +95 °C
Humidity range: 10 to 98 % r.h.
Temperature and humidity deviations (steady-state, per IEC 60068-3-5):
Temporal temperature fluctuation at center of workspace: ± 0.3 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 (temperature gradient): 1 to 3
Temporal humidity fluctuation at center of workspace: ± 3 to ± 5 % r.H.
Operational data:
Test chamber illumination: Halogen bulb 12V, 20W
Rated voltage: 1/N / PE AC 230 V ± 10% 50 Hz
Rated power: 2.5 kW
Rated current: 11 A
Protection (on-site): 16A slow-blow
Heat emission (air-cooled chamber):
Gjdpfx Aetr Dinocuobu
Maximum heat emission to ambient: 1700 W
Refrigerant: R-452A / R23
Weight: 140 kg
Important safety information for the buyer!
The following points will be completed on our offered chambers prior to delivery:
1. Functional check and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certificate
4. Upon successful completion, the chamber undergoes a documented test run.
Condition: used
Scope of delivery: (see picture)
(Technical data subject to change and error!)
We are happy to answer further questions by phone.
Skelbimas verčiamas automatiškai, todėl jame gali būtų vertimo klaidų.
Tiekėjas
Pastaba: Užsiregistruokite nemokamai arba prisijunkite, kad gautumėte visą informaciją.
Pateikti užklausą
Telefonas & Faksas
+49 2861 ... skelbimai
Jūsų skelbimas sėkmingai pašalintas
Įvyko klaida