Klimato bandymo kamera su drėgme 190 litrųVötsch
VC 7018 -70 bis 180°C
Klimato bandymo kamera su drėgme 190 litrų
Vötsch
VC 7018 -70 bis 180°C
Sąlyga
Naudotas
Vieta
Borken 

Rodyti vaizdus
Rodyti žemėlapį
Duomenys apie mašiną
- Įrenginio aprašas:
- Klimato bandymo kamera su drėgme 190 litrų
- Gamintojas:
- Vötsch
- Modelis:
- VC 7018 -70 bis 180°C
- Sąlyga:
- labai geros būklės (naudotas)
Kaina ir vieta
- Vieta:
- Einsteinstraße 8a, 46325 Borken, DE
Skambinti
Pasiūlymo informacija
- Sąrašo ID:
- A19038856
- Nuorodos Nr.:
- 24613
- Naujinta paskutinį kartą:
- Data 2025.04.29
Aprašymas
Vötsch
Type: VC 7018
Vötsch Climate Test Chamber VC 7018 Water-Cooled
Control Unit: "Touch Panel"
All control and operation commands can be executed by simply touching the function icons on the "Touch Panel" control unit.
Leveling Feet
To compensate for uneven floors and to ensure adequate ventilation of the machine section, the test chamber is equipped with adjustable feet.
Feedthroughs
The test chamber is equipped with feedthroughs on both the right and left sides. These allow measuring cables and test devices to be routed into the test chamber. Standard feedthroughs installed:
R1: nominal width 125 mm
L1: nominal width 50 mm
Test Chamber Dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing Dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Specifications for Temperature Testing:
Temperature Range: -70°C to +180°C
Fsdpfxswgaykj Acujgh
time-related ±0.1 to ±0.5 K
spatial ±0.5 to ±2.0 K
Temperature Change Rate according to IEC 60068-3-5
Heating: 4 K/min
Cooling: 2.3 K/min
Specifications for Climatic Testing:
Temperature Range: -10°C to +95°C
Humidity Range: 10% to 98% r.h.
Temperature deviation over time in center of usable space ±0.1 to ±0.3 K
Temperature deviation spatially ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity deviation over time in center of usable space ±1 to ±3 % r.h.
Electrical Connection:
Rated voltage: 3/N/PE AC 400V ±10 50Hz
Rated power: 5.9 kW
Rated current: 12.0 A
Connection cable: 3.5 m
Protection: 16 A slow-blow, to be installed on site
Refrigerants: R-404A and R-23
Test chamber volume: approx. 190 liters
Weight: approx. 460 kg net
For your safety as a buyer, please note the following information!
The following steps are completed on all chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications and technical data subject to changes and errors!)
For further questions we are happy to assist you by phone.
Skelbimas verčiamas automatiškai, todėl jame gali būtų vertimo klaidų.
Type: VC 7018
Vötsch Climate Test Chamber VC 7018 Water-Cooled
Control Unit: "Touch Panel"
All control and operation commands can be executed by simply touching the function icons on the "Touch Panel" control unit.
Leveling Feet
To compensate for uneven floors and to ensure adequate ventilation of the machine section, the test chamber is equipped with adjustable feet.
Feedthroughs
The test chamber is equipped with feedthroughs on both the right and left sides. These allow measuring cables and test devices to be routed into the test chamber. Standard feedthroughs installed:
R1: nominal width 125 mm
L1: nominal width 50 mm
Test Chamber Dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing Dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Specifications for Temperature Testing:
Temperature Range: -70°C to +180°C
Fsdpfxswgaykj Acujgh
time-related ±0.1 to ±0.5 K
spatial ±0.5 to ±2.0 K
Temperature Change Rate according to IEC 60068-3-5
Heating: 4 K/min
Cooling: 2.3 K/min
Specifications for Climatic Testing:
Temperature Range: -10°C to +95°C
Humidity Range: 10% to 98% r.h.
Temperature deviation over time in center of usable space ±0.1 to ±0.3 K
Temperature deviation spatially ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity deviation over time in center of usable space ±1 to ±3 % r.h.
Electrical Connection:
Rated voltage: 3/N/PE AC 400V ±10 50Hz
Rated power: 5.9 kW
Rated current: 12.0 A
Connection cable: 3.5 m
Protection: 16 A slow-blow, to be installed on site
Refrigerants: R-404A and R-23
Test chamber volume: approx. 190 liters
Weight: approx. 460 kg net
For your safety as a buyer, please note the following information!
The following steps are completed on all chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications and technical data subject to changes and errors!)
For further questions we are happy to assist you by phone.
Skelbimas verčiamas automatiškai, todėl jame gali būtų vertimo klaidų.
Tiekėjas
Pastaba: Užsiregistruokite nemokamai arba prisijunkite, kad gautumėte visą informaciją.
Pateikti užklausą
Telefonas & Faksas
+49 2861 ... skelbimai
Šie skelbimai taip pat gali jus sudominti.
mažas skelbimas

1 181 km
Klimato bandymo kamera su drėgme 190 litrų
VötschVC 7018 -70 bis 180°C
VötschVC 7018 -70 bis 180°C
Jūsų skelbimas sėkmingai pašalintas
Įvyko klaida