aprašymas
Rohde & Schwarz
EMI Test Receiver
Model: ESPI3
Frequency Range: 9 kHz to 3 GHz
IF Resolution Bandwidths (RBW): 200 Hz (CISPR), 9 kHz (CISPR), 120 kHz (CISPR), 1 MHz plus 10 Hz to 10 MHz in 1-3-10 steps
CISPR Bandwidths: < 150 kHz = 200 Hz, 150 kHz–30 MHz = 9 kHz, > 30 MHz = 120 kHz
Detectors: Max Peak, Min Peak, Quasi-Peak (CISPR 16), Average, RMS
Up to 3 detectors can be activated simultaneously
Input Attenuation: 0 dB to 70 dB in 10 dB steps
Optional Preamplifier ESPI-B2: 9 kHz to 3 GHz, 20 dB gain
Noise Figure: approx. 18 dB without preamplifier, approx. 10 dB with preamplifier
Ndedpfxjzimlvs Af Hja
Freely adjustable start and stop frequency
Step size can match receive frequency (harmonic measurements)
Display Units: dBm, dBµV, dBµA, dBpW, dBpT
Measurement Functions: EMI according to CISPR, APD, CCDF, Continuous and Single Measurement
Weight: 1 kg
Condition: used
Scope of delivery: (See picture)
(Specifications subject to change and error!)
For further questions, please contact us by phone.
Skelbimas buvo automatiškai išverstas. Galimos vertimo klaidos.
EMI Test Receiver
Model: ESPI3
Frequency Range: 9 kHz to 3 GHz
IF Resolution Bandwidths (RBW): 200 Hz (CISPR), 9 kHz (CISPR), 120 kHz (CISPR), 1 MHz plus 10 Hz to 10 MHz in 1-3-10 steps
CISPR Bandwidths: < 150 kHz = 200 Hz, 150 kHz–30 MHz = 9 kHz, > 30 MHz = 120 kHz
Detectors: Max Peak, Min Peak, Quasi-Peak (CISPR 16), Average, RMS
Up to 3 detectors can be activated simultaneously
Input Attenuation: 0 dB to 70 dB in 10 dB steps
Optional Preamplifier ESPI-B2: 9 kHz to 3 GHz, 20 dB gain
Noise Figure: approx. 18 dB without preamplifier, approx. 10 dB with preamplifier
Ndedpfxjzimlvs Af Hja
Freely adjustable start and stop frequency
Step size can match receive frequency (harmonic measurements)
Display Units: dBm, dBµV, dBµA, dBpW, dBpT
Measurement Functions: EMI according to CISPR, APD, CCDF, Continuous and Single Measurement
Weight: 1 kg
Condition: used
Scope of delivery: (See picture)
(Specifications subject to change and error!)
For further questions, please contact us by phone.
Skelbimas buvo automatiškai išverstas. Galimos vertimo klaidos.
Siųsti užklausą
Telefonas & Faksas
+49 2861 ... skelbimai
Šie skelbimai taip pat gali jus sudominti.
Mažas skelbimas
Tallinn
476 km
AXI - PCB AOI ir rentgeno aparatas kartu
GoepelXLine 3D X-Ray & AOI
GoepelXLine 3D X-Ray & AOI
Mažas skelbimas
Nagold
1 271 km
2D AOI sistema
YamahaYSi12
YamahaYSi12
Mažas skelbimas
Tallinn
476 km
Rentgeno aparatas
Comet YxlonCougar ECO
Comet YxlonCougar ECO
Mažas skelbimas
Veenendaal
1 256 km
Rentgeno patikra
Seamark X-ray machine5600
Seamark X-ray machine5600
Mažas skelbimas
Berlin
748 km
IKT testavimo sistema
KEYSIGHTI3070
KEYSIGHTI3070
Mažas skelbimas
Vokietija
999 km
Stabilizatorius
KeyenceSJ-H
KeyenceSJ-H
Mažas skelbimas
Veenendaal
1 256 km
Surinkimo mašina
Vitronics Soltec mySelective 67466746
Vitronics Soltec mySelective 67466746
Jūsų skelbimas sėkmingai pašalintas
Įvyko klaida