Klimatinė bandymų kamera temperatūra: -70 iki 180°CWeiss explosionsgeschützt
WK-600/70 (I)-(II) 2 G EEx
Klimatinė bandymų kamera temperatūra: -70 iki 180°C
Weiss explosionsgeschützt
WK-600/70 (I)-(II) 2 G EEx
Būklė
Naudotas
Vieta
Borken 

Duomenys apie mašiną
- Mašinos pavadinimas:
- Klimatinė bandymų kamera temperatūra: -70 iki 180°C
- Gamintojas:
- Weiss explosionsgeschützt
- modelis:
- WK-600/70 (I)-(II) 2 G EEx
- Būklė:
- labai geros būklės (naudotas)
Kaina ir vieta
- Vieta:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Skambinti
Pasiūlymo informacija
- Skelbimo ID:
- A22241172
- Nuorodos numeris:
- 20744
- Atnaujinimas:
- paskutinį kartą atnaujinta 01.07.2026
aprašymas
Weiss
Model: WK-600/70 (I)-(II) 2 G EEx /22605147
Weiss Climate Chamber, Water-Cooled
(Test Chamber Explosion-Proof)
INERTING WITH NITROGEN / EXPLOSION-PROOF TEST CHAMBER
Technical Data:
Test Chamber Designation: WK-600/70 (I)-(II) 2 G EEx
External dimensions with hinges and door lock:
Height 1995 mm, Width 1090 mm, Depth 1660 mm
External dimensions without hinges and door lock:
Height 1995 mm, Width 1000 mm, Depth 1660 mm
Test chamber volume: approx. 600 liters
Cooling / Heating Operation: -70 to +180°C
Climate Operation: 10 – 95°C
Humidity: 10...98 % rH
Temperature Change Rate:
Cooling approx. 2.5 K/min
Heating approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 14 kW
Rated current: 25 A
Required fuse (on site): 32 A slow-blow
Permissible test specimen weight:
Total load of grates: 80 kg
Test chamber floor: 80 kg, insert grate: 40 kg
Weight: 800 kg
Refrigerant: R 404A/R 23
(The evaporator of the air conditioning unit was replaced)
Important safety information for you as buyer:
The following points are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. Upon successful inspection, chambers are subjected to documented test runs.
Condition: used / gebraucht
Nodpfjzh D Rysx Ag Holf
Scope of delivery: (see picture)
(Specifications and technical details subject to change and errors!)
For further questions, please feel free to contact us by phone.
Skelbimas buvo automatiškai išverstas. Galimos vertimo klaidos.
Model: WK-600/70 (I)-(II) 2 G EEx /22605147
Weiss Climate Chamber, Water-Cooled
(Test Chamber Explosion-Proof)
INERTING WITH NITROGEN / EXPLOSION-PROOF TEST CHAMBER
Technical Data:
Test Chamber Designation: WK-600/70 (I)-(II) 2 G EEx
External dimensions with hinges and door lock:
Height 1995 mm, Width 1090 mm, Depth 1660 mm
External dimensions without hinges and door lock:
Height 1995 mm, Width 1000 mm, Depth 1660 mm
Test chamber volume: approx. 600 liters
Cooling / Heating Operation: -70 to +180°C
Climate Operation: 10 – 95°C
Humidity: 10...98 % rH
Temperature Change Rate:
Cooling approx. 2.5 K/min
Heating approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 14 kW
Rated current: 25 A
Required fuse (on site): 32 A slow-blow
Permissible test specimen weight:
Total load of grates: 80 kg
Test chamber floor: 80 kg, insert grate: 40 kg
Weight: 800 kg
Refrigerant: R 404A/R 23
(The evaporator of the air conditioning unit was replaced)
Important safety information for you as buyer:
The following points are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. Upon successful inspection, chambers are subjected to documented test runs.
Condition: used / gebraucht
Nodpfjzh D Rysx Ag Holf
Scope of delivery: (see picture)
(Specifications and technical details subject to change and errors!)
For further questions, please feel free to contact us by phone.
Skelbimas buvo automatiškai išverstas. Galimos vertimo klaidos.