Klimatinė bandymų kamera, 990 litrųWeiss – 40…+ 180°C
WK11-1000/40 mit Zander K-MT 2
Klimatinė bandymų kamera, 990 litrų
Weiss – 40…+ 180°C
WK11-1000/40 mit Zander K-MT 2
Sąlyga
Naudotas
Vieta
Borken 

Rodyti vaizdus
Rodyti žemėlapį
Duomenys apie mašiną
- Įrenginio aprašas:
- Klimatinė bandymų kamera, 990 litrų
- Gamintojas:
- Weiss – 40…+ 180°C
- Modelis:
- WK11-1000/40 mit Zander K-MT 2
- Sąlyga:
- labai geros būklės (naudotas)
Kaina ir vieta
- Vieta:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Skambinti
Pasiūlymo informacija
- Sąrašo ID:
- A20761877
- Nuorodos Nr.:
- 24929
- Naujinta paskutinį kartą:
- Data 2026.01.12
Aprašymas
Weiss Type: WK11-1000/40
For sale is a professional climate test chamber Weiss Umwelttechnik WT-WK 1000/40
with fully automatic cold-regenerating adsorption dryer.
The existing fittings in the test chamber can be removed if required.
Currently, due to these fittings, the control cabinet is limited
to a temperature range of −40°C to +60°C.
After removing these fittings, the manufacturer can restore the standard temperature range
of −40°C to +180°C, as the current fittings are not suitable for higher temperatures.
The unit is ideal for precise temperature and humidity testing of components,
assemblies, and devices.
Perfect for applications in industry, development, quality assurance, and research.
Weiss climate test chamber, water-cooled
Specifications for temperature tests:
Temperature range: -40°C to +60°C
Temperature fluctuation (temporal, in center of working space): ±0.1 to ±0.5 K
Temperature deviation (spatial): ±0.5 to ±2.0 K
Temperature rate of change:
Giedpfjx Hxkzex Abdol
Heating: 4 K/min
Cooling: 3 K/min
Specifications for climate tests:
Temperature range: +10°C to +95°C
Humidity range: 10 to 98 % RH
Temperature fluctuation (temporal, in center of working space): ±0.1 to ±0.3 K
Temperature deviation (spatial): ±0.5 to ±1 K
Humidity fluctuation (temporal, in center of working space): ±1 to ±3% RH
Heat compensation:
Within +25°C to +95°C
to a relative humidity of up to 90%: 500 W
Humidification system data:
Tank volume: 20 l
Water quality: demineralized
pH value: 6 to 7
Conductivity: 5 to 20 µS/cm³
Water consumption at constant +40°C, 92% RH: 21 l/24 h
Temperature gradient (according to IEC 60068-3-5): 1 to 2 K
Test chamber inner dimensions: Height: 950 mm, Width: 1100 mm, Depth: 950 mm
External dimensions: Height: 1980 mm, Width: 1385 mm, Depth: 1850 mm
Test chamber volume: approx. 990 liters
Rated voltage: 3/N / PE AC 400 V +10% 50 Hz
Rated power: 11.5 kW, Rated current: 22.0 A
Refrigerant: R 404A
Weight: 840 kg
For your safety as a buyer, please note the following:
The following points are routinely carried out on chambers we offer:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, a documented trial run is performed on the chambers.
Condition: used
Scope of delivery: (see picture)
(Subject to changes and errors in the technical data, specifications)
If you have further questions, we are happy to answer them by phone.
Skelbimas verčiamas automatiškai, todėl jame gali būtų vertimo klaidų.
For sale is a professional climate test chamber Weiss Umwelttechnik WT-WK 1000/40
with fully automatic cold-regenerating adsorption dryer.
The existing fittings in the test chamber can be removed if required.
Currently, due to these fittings, the control cabinet is limited
to a temperature range of −40°C to +60°C.
After removing these fittings, the manufacturer can restore the standard temperature range
of −40°C to +180°C, as the current fittings are not suitable for higher temperatures.
The unit is ideal for precise temperature and humidity testing of components,
assemblies, and devices.
Perfect for applications in industry, development, quality assurance, and research.
Weiss climate test chamber, water-cooled
Specifications for temperature tests:
Temperature range: -40°C to +60°C
Temperature fluctuation (temporal, in center of working space): ±0.1 to ±0.5 K
Temperature deviation (spatial): ±0.5 to ±2.0 K
Temperature rate of change:
Giedpfjx Hxkzex Abdol
Heating: 4 K/min
Cooling: 3 K/min
Specifications for climate tests:
Temperature range: +10°C to +95°C
Humidity range: 10 to 98 % RH
Temperature fluctuation (temporal, in center of working space): ±0.1 to ±0.3 K
Temperature deviation (spatial): ±0.5 to ±1 K
Humidity fluctuation (temporal, in center of working space): ±1 to ±3% RH
Heat compensation:
Within +25°C to +95°C
to a relative humidity of up to 90%: 500 W
Humidification system data:
Tank volume: 20 l
Water quality: demineralized
pH value: 6 to 7
Conductivity: 5 to 20 µS/cm³
Water consumption at constant +40°C, 92% RH: 21 l/24 h
Temperature gradient (according to IEC 60068-3-5): 1 to 2 K
Test chamber inner dimensions: Height: 950 mm, Width: 1100 mm, Depth: 950 mm
External dimensions: Height: 1980 mm, Width: 1385 mm, Depth: 1850 mm
Test chamber volume: approx. 990 liters
Rated voltage: 3/N / PE AC 400 V +10% 50 Hz
Rated power: 11.5 kW, Rated current: 22.0 A
Refrigerant: R 404A
Weight: 840 kg
For your safety as a buyer, please note the following:
The following points are routinely carried out on chambers we offer:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, a documented trial run is performed on the chambers.
Condition: used
Scope of delivery: (see picture)
(Subject to changes and errors in the technical data, specifications)
If you have further questions, we are happy to answer them by phone.
Skelbimas verčiamas automatiškai, todėl jame gali būtų vertimo klaidų.
Tiekėjas
Pastaba: Užsiregistruokite nemokamai arba prisijunkite, kad gautumėte visą informaciją.
Pateikti užklausą
Telefonas & Faksas
+49 2861 ... skelbimai
Šie skelbimai taip pat gali jus sudominti.
Mažas skelbimas
Goudriaan
1 303 km
Mulčeris
Boxer AgriMaster 175
Boxer AgriMaster 175
Jūsų skelbimas sėkmingai pašalintas
Įvyko klaida