TIRA
Type: TCZ 4022 S -2K
Description: Air-cooled Climate Simulation Chamber
System Composition:
The system consists of the following main assemblies:
- Walk-in, insulated chamber
- Air treatment compartment
- Humidification system
- Machinery compartment
- Control cabinet
Technical Data:
Performance range for temperature testing:
- Temperature range: -40...+140°C
- Temperature stability, in supply air (temporal): ≤ ± 0.5°C
(without thermal test chamber load, in accordance with DIN 50011 T13 / EN 60068)
- Temperature stability, in supply air (spatial): ≤ ± 1.0°C
(without thermal test chamber load, in accordance with DIN 50011 / EN 60068)
- Heating rate (per DIN 50011): approx. 2.0 K/min
(without thermal test chamber load per DIN 50011 / EN 60068, or test specimen in the temperature range -30°C...+85°C)
- Cooling rate (per DIN 50011): approx. 2.0 K/min
(without thermal test chamber load per DIN 50011 / EN 60068, or test specimen in the temperature range -30°C...+85°C)
Performance range for climate testing:
- Temperature range: +10...+90°C
- Humidity working range: 10...approx. 95% rh
(without thermal chamber load)
- Dew point temperature range: +5...+89°C
(without thermal chamber load)
- Humidity stability (in supply air, temporal): ≤ ±2.5% rh
(measured in supply air)
Performance range for climate testing with heat compensation:
- Temperature range: +15...+80°C
- Humidity: 15...approx. 80% rh
(without thermal chamber load, with max. 16 kW heat compensation)
- Dew point temperature range: +10...+74°C
(without thermal chamber load)
Dimensions:
- Test chamber (W x D x H): approx. 2260 x 4648 x 2260 mm
- External dimensions (W x D x H): approx. 2660 x 6460 x 2800 mm
- Clear door opening, test chamber door (W x H): 2260 x 2260 mm
- Climate module KB 127 (W x D x H): 1700 x 800 x 1400 mm
- Control cabinet (W x D x H): 800 x 500 x 2000 mm
Design Features:
- Air guidance:
* Supply air: Perforated sheet at the rear wall, in the ceiling area
* Exhaust air: Perforated sheet at the rear wall, in the floor area
- Temperature control:
* Direct cooling via evaporation of refrigerant in a finned heat exchanger
* Heating via electric resistance heater
- Dehumidification:
* Direct dehumidification by evaporating refrigerant in a heat exchanger
- Interior cladding: Stainless steel
- Exterior cladding: Galvanized, powder-coated steel sheet
- Floor design: Stainless steel, floor load 15,000 N/m²
- Wheel load (bearing surface ≥4 cm²): 1,500 N/wheel
- Door: Double-wing door, stainless steel, lacquered exterior with viewing window (W x H) 1,000 x 1,000 mm
- Chamber lighting: 4 spotlights at 500 W each
- Insulation: Double-layer, 80 mm PUR foam, 120 mm mineral wool
- Refrigeration unit (1 pc.): Blitzer 6G-30.2Y
- Refrigerant: R449A
- Refrigeration oil: SEZ 32
- Steam humidifier (1 pc.): EDB 40
Color scheme:
- Chamber: RAL 9010, white
- Door: RAL 9010, white
- Machine unit: RAL 7032, pebble grey
- Control cabinet: RAL 7032, pebble grey
Fedsvx S Hhopfx Acujgh
Weights:
- Total system: approx. 4,900 kg
- Machine set KB 127: approx. 750 kg
- Control cabinet: approx. 120 kg
- Humidifying unit: approx. 64 kg
Connections:
- Rated voltage: 400 V +6%/-10% 3/PE N 50Hz
- Rated power: 95 kW
- Rated current: 150 A
Skelbimas verčiamas automatiškai, todėl jame gali būtų vertimo klaidų.
Type: TCZ 4022 S -2K
Description: Air-cooled Climate Simulation Chamber
System Composition:
The system consists of the following main assemblies:
- Walk-in, insulated chamber
- Air treatment compartment
- Humidification system
- Machinery compartment
- Control cabinet
Technical Data:
Performance range for temperature testing:
- Temperature range: -40...+140°C
- Temperature stability, in supply air (temporal): ≤ ± 0.5°C
(without thermal test chamber load, in accordance with DIN 50011 T13 / EN 60068)
- Temperature stability, in supply air (spatial): ≤ ± 1.0°C
(without thermal test chamber load, in accordance with DIN 50011 / EN 60068)
- Heating rate (per DIN 50011): approx. 2.0 K/min
(without thermal test chamber load per DIN 50011 / EN 60068, or test specimen in the temperature range -30°C...+85°C)
- Cooling rate (per DIN 50011): approx. 2.0 K/min
(without thermal test chamber load per DIN 50011 / EN 60068, or test specimen in the temperature range -30°C...+85°C)
Performance range for climate testing:
- Temperature range: +10...+90°C
- Humidity working range: 10...approx. 95% rh
(without thermal chamber load)
- Dew point temperature range: +5...+89°C
(without thermal chamber load)
- Humidity stability (in supply air, temporal): ≤ ±2.5% rh
(measured in supply air)
Performance range for climate testing with heat compensation:
- Temperature range: +15...+80°C
- Humidity: 15...approx. 80% rh
(without thermal chamber load, with max. 16 kW heat compensation)
- Dew point temperature range: +10...+74°C
(without thermal chamber load)
Dimensions:
- Test chamber (W x D x H): approx. 2260 x 4648 x 2260 mm
- External dimensions (W x D x H): approx. 2660 x 6460 x 2800 mm
- Clear door opening, test chamber door (W x H): 2260 x 2260 mm
- Climate module KB 127 (W x D x H): 1700 x 800 x 1400 mm
- Control cabinet (W x D x H): 800 x 500 x 2000 mm
Design Features:
- Air guidance:
* Supply air: Perforated sheet at the rear wall, in the ceiling area
* Exhaust air: Perforated sheet at the rear wall, in the floor area
- Temperature control:
* Direct cooling via evaporation of refrigerant in a finned heat exchanger
* Heating via electric resistance heater
- Dehumidification:
* Direct dehumidification by evaporating refrigerant in a heat exchanger
- Interior cladding: Stainless steel
- Exterior cladding: Galvanized, powder-coated steel sheet
- Floor design: Stainless steel, floor load 15,000 N/m²
- Wheel load (bearing surface ≥4 cm²): 1,500 N/wheel
- Door: Double-wing door, stainless steel, lacquered exterior with viewing window (W x H) 1,000 x 1,000 mm
- Chamber lighting: 4 spotlights at 500 W each
- Insulation: Double-layer, 80 mm PUR foam, 120 mm mineral wool
- Refrigeration unit (1 pc.): Blitzer 6G-30.2Y
- Refrigerant: R449A
- Refrigeration oil: SEZ 32
- Steam humidifier (1 pc.): EDB 40
Color scheme:
- Chamber: RAL 9010, white
- Door: RAL 9010, white
- Machine unit: RAL 7032, pebble grey
- Control cabinet: RAL 7032, pebble grey
Fedsvx S Hhopfx Acujgh
Weights:
- Total system: approx. 4,900 kg
- Machine set KB 127: approx. 750 kg
- Control cabinet: approx. 120 kg
- Humidifying unit: approx. 64 kg
Connections:
- Rated voltage: 400 V +6%/-10% 3/PE N 50Hz
- Rated power: 95 kW
- Rated current: 150 A
Skelbimas verčiamas automatiškai, todėl jame gali būtų vertimo klaidų.