Temperatūros aušinimo blokas (TCU)Single
Water Advanced WP7
Temperatūros aušinimo blokas (TCU)
Single
Water Advanced WP7
Sąlyga
Naujas
Vieta
Hochdorf 

Rodyti vaizdus
Rodyti žemėlapį
Duomenys apie mašiną
- Įrenginio aprašas:
- Temperatūros aušinimo blokas (TCU)
- Gamintojas:
- Single
- Modelis:
- Water Advanced WP7
- Sąlyga:
- naujas
Kaina ir vieta
- Vieta:
- Ostring 17-19, 73269 Hochdorf, DE
- nuoma:
- yra įmanoma
Skambinti
Pasiūlymo informacija
- Sąrašo ID:
- A6050776
- Nuorodos Nr.:
- Water Advanced WP7
- Naujinta paskutinį kartą:
- Data 2024.11.21
Aprašymas
*TECHNICAL SPECIFICATIONS:
Heating capacity: up to 54 kW
Cooling capacity: up to 300 kW
Medium: Water up to 200°C
Maximum external volume: 43 l at 200°C
Max. flow rate: up to 230 l/min
Max. delivery pressure: up to 8.3 bar
Motor power: up to 3 kW
Dimensions LxWxH: 1,460 x 525 x 1,200 mm
Weight: approx. 330 kg
Circulating medium connection: Flange DN40 (DIN EN 1092-1), Form B1
*EQUIPMENT HIGHLIGHTS:
-Control and regulation unit: Smart Controller (7" touch display)
-Heating control via solid-state relay
-Control cabinet IP54, externally ventilated
-Expansion tank, heater, and piping made of stainless steel
-Heating via stainless steel tubular heaters made of Incolloy
-Strainer (circulation)
-Unit ready for connection and mounted on casters, 2 of which are steerable and with brake
-Cooling and filling controlled by solenoid valve
-Configurable automatic filling via cold water supply or separate connection (factory setting: via cooling water supply)
-Flow measurement based on the differential pressure principle
-Level monitoring using magnetic float switch
-Automatic temperature-dependent system shut-off (not for WP7-90)
-Flow monitoring by detecting the flow rate
-Bypass between supply and return with reduced cross-section
-Dirt filter in cooling water supply, filling, and return of the circulation system
-Continuous bypass of the heat exchanger via 3-way motorized control valve (WP7-180/200)
-System pressure monitoring via pressure transmitter in expansion tank (WP7-150/180/200)
-Booster pump for system filling (WP7-180/200, optional for other models)
-Safety temperature limiter (STB) in heater and supply (WP7-200)
-Pressure gauge in supply line at rear of unit
-Circulation circuit thermally insulated (WP7-150/180/200)
Visit our website for further details or for other performance classes.
Kodpfx Acsg Ey T Esuedu
*This equipment complies with European Directives. Other directives and standards are fulfilled only if listed in the order confirmation. This technical specification refers to the standard configuration; customer requests deviating from the standard will be specified in quotations and order confirmations.
Skelbimas verčiamas automatiškai, todėl jame gali būtų vertimo klaidų.
Heating capacity: up to 54 kW
Cooling capacity: up to 300 kW
Medium: Water up to 200°C
Maximum external volume: 43 l at 200°C
Max. flow rate: up to 230 l/min
Max. delivery pressure: up to 8.3 bar
Motor power: up to 3 kW
Dimensions LxWxH: 1,460 x 525 x 1,200 mm
Weight: approx. 330 kg
Circulating medium connection: Flange DN40 (DIN EN 1092-1), Form B1
*EQUIPMENT HIGHLIGHTS:
-Control and regulation unit: Smart Controller (7" touch display)
-Heating control via solid-state relay
-Control cabinet IP54, externally ventilated
-Expansion tank, heater, and piping made of stainless steel
-Heating via stainless steel tubular heaters made of Incolloy
-Strainer (circulation)
-Unit ready for connection and mounted on casters, 2 of which are steerable and with brake
-Cooling and filling controlled by solenoid valve
-Configurable automatic filling via cold water supply or separate connection (factory setting: via cooling water supply)
-Flow measurement based on the differential pressure principle
-Level monitoring using magnetic float switch
-Automatic temperature-dependent system shut-off (not for WP7-90)
-Flow monitoring by detecting the flow rate
-Bypass between supply and return with reduced cross-section
-Dirt filter in cooling water supply, filling, and return of the circulation system
-Continuous bypass of the heat exchanger via 3-way motorized control valve (WP7-180/200)
-System pressure monitoring via pressure transmitter in expansion tank (WP7-150/180/200)
-Booster pump for system filling (WP7-180/200, optional for other models)
-Safety temperature limiter (STB) in heater and supply (WP7-200)
-Pressure gauge in supply line at rear of unit
-Circulation circuit thermally insulated (WP7-150/180/200)
Visit our website for further details or for other performance classes.
Kodpfx Acsg Ey T Esuedu
*This equipment complies with European Directives. Other directives and standards are fulfilled only if listed in the order confirmation. This technical specification refers to the standard configuration; customer requests deviating from the standard will be specified in quotations and order confirmations.
Skelbimas verčiamas automatiškai, todėl jame gali būtų vertimo klaidų.
Tiekėjas