Temperatūros aušinimo įrenginys (TCU)Single
Easitemp 95/6/45 (Easi95.A)
Temperatūros aušinimo įrenginys (TCU)
Single
Easitemp 95/6/45 (Easi95.A)
Sąlyga
Naujas
Vieta
Hochdorf 

Rodyti vaizdus
Rodyti žemėlapį
Duomenys apie mašiną
- Įrenginio aprašas:
- Temperatūros aušinimo įrenginys (TCU)
- Gamintojas:
- Single
- Modelis:
- Easitemp 95/6/45 (Easi95.A)
- Sąlyga:
- naujas
Kaina ir vieta
- Vieta:
- Ostring 17, 73269 Hochdorf, Deutschland
- nuoma:
- yra įmanoma
Skambinti
Pasiūlymo informacija
- Sąrašo ID:
- A4572711
- Nuorodos Nr.:
- Easi95.A
- Naujinta paskutinį kartą:
- Data 2024.11.21
Aprašymas
*Technical Standard Specification:
Device Type: 6/95
Heating Capacity: 6 kW
Cooling Capacity: 45 kW
Medium: Water up to 95°C
Maximum External Volume: 50 l at 95°C
*Hydraulic Functional Features:
- Cooling and filling controlled by solenoid valve
- Automatic filling via cooling water or manual filling (option)
- Level monitoring by magnetic float switch
- Dirt filter in return flow and cooling water inlet
- Reversing circuit for leak-stop operation
- Manual tool drainage via leak-stop operation and actuation of a vent valve at the rear of the unit
- Fill duration monitoring and aquatimer
- Adjustable pump overrun
- Adjustable temperature alarm
- Options: filling nozzle, interface cable, mechanical flow meter
*Electrical Functional Features:
- Control and regulation unit SBCmini, with relay for collective alarm, 230V, located at the rear of the controller on terminal strip
- Heater control via SSR
- Control box IP54
- 20mA TTY interface; pin assignment Arburg
- Cekon plug 16A
*General Features:
- Corrosion-resistant components (stainless steel, brass)
Kodpfefnvvisx Acuonc
- Heating via stainless steel tubular heater made of Incolloy
- Device mounted on castors, two of which are steerable with brakes
- Additional temperature safety for secure shutdown of the heater via heater circuit protector
*Cooling:
Cooling capacity: 45 kW (stainless steel plate heat exchanger)
Cooling water connection: G3/8" female thread
(Capacity based on 80°C flow temperature, 15°C cooling water temperature, and a pressure differential between cooling water inlet and outlet of 3 bar)
*Pump:
Type: T401
Max. delivery rate: 40 l/min
Max. delivery pressure: 3.8 bar
Motor power: 0.5 kW
Design: submersible pump / peripheral impeller
*Dimensions / Weight / Colors
Dimensions (L/W/H): 514 mm x 238 mm x 493 mm (without connections)
Weight: approx. 30 kg
Color: housing: RAL 7035 light grey; front door: RAL 5015 sky blue
*Connections:
Circulating medium: G1/2" female thread
Cooling water: G3/8" female thread
Filling (option)
*This device complies with European directives. Other directives and standards are only met if stated in the order confirmation. This technical specification reflects the standard equipment; customer requests deviating from the standard are listed in offers or order confirmations.
Skelbimas verčiamas automatiškai, todėl jame gali būtų vertimo klaidų.
Device Type: 6/95
Heating Capacity: 6 kW
Cooling Capacity: 45 kW
Medium: Water up to 95°C
Maximum External Volume: 50 l at 95°C
*Hydraulic Functional Features:
- Cooling and filling controlled by solenoid valve
- Automatic filling via cooling water or manual filling (option)
- Level monitoring by magnetic float switch
- Dirt filter in return flow and cooling water inlet
- Reversing circuit for leak-stop operation
- Manual tool drainage via leak-stop operation and actuation of a vent valve at the rear of the unit
- Fill duration monitoring and aquatimer
- Adjustable pump overrun
- Adjustable temperature alarm
- Options: filling nozzle, interface cable, mechanical flow meter
*Electrical Functional Features:
- Control and regulation unit SBCmini, with relay for collective alarm, 230V, located at the rear of the controller on terminal strip
- Heater control via SSR
- Control box IP54
- 20mA TTY interface; pin assignment Arburg
- Cekon plug 16A
*General Features:
- Corrosion-resistant components (stainless steel, brass)
Kodpfefnvvisx Acuonc
- Heating via stainless steel tubular heater made of Incolloy
- Device mounted on castors, two of which are steerable with brakes
- Additional temperature safety for secure shutdown of the heater via heater circuit protector
*Cooling:
Cooling capacity: 45 kW (stainless steel plate heat exchanger)
Cooling water connection: G3/8" female thread
(Capacity based on 80°C flow temperature, 15°C cooling water temperature, and a pressure differential between cooling water inlet and outlet of 3 bar)
*Pump:
Type: T401
Max. delivery rate: 40 l/min
Max. delivery pressure: 3.8 bar
Motor power: 0.5 kW
Design: submersible pump / peripheral impeller
*Dimensions / Weight / Colors
Dimensions (L/W/H): 514 mm x 238 mm x 493 mm (without connections)
Weight: approx. 30 kg
Color: housing: RAL 7035 light grey; front door: RAL 5015 sky blue
*Connections:
Circulating medium: G1/2" female thread
Cooling water: G3/8" female thread
Filling (option)
*This device complies with European directives. Other directives and standards are only met if stated in the order confirmation. This technical specification reflects the standard equipment; customer requests deviating from the standard are listed in offers or order confirmations.