Here we offer a shock test chamber.
Water-cooled temperature shock test chamber
Two-chamber design
Hot Chamber:
Temperature range of the hot chamber: +50°C to +220°C
Cedpfx Aaji Az Ego Ssrh
Temporal temperature deviation at the center of the usable space: ±1 K
Spatial temperature deviation: ±2 K
Temperature change rate:
Heating: 11 K/min
Cold Chamber:
Temperature range of the cold chamber: -65°C to +70°C
Temporal temperature deviation at the center of the usable space: ±1 K
Spatial temperature deviation: ±2 K
Temperature change rate:
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Temperature range hot chamber: +50°C to +220°C
Temperature range cold chamber: -80°C to +70°C
Test area dimensions: Width 470mm x Depth 650mm x Height 410mm
External dimensions: Width 930mm x Depth 2115mm x Height 1970+mm
Nominal power: 10 kW
Rated current: 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerants: R404A / R23
Operating hours: 27,903 h
Weight: 1,000 kg
For your safety as a buyer, please note the following information!
The following work is carried out on all test chambers we offer prior to sale:
1. Functional test and replacement of necessary components
2. New filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a test run, which is monitored using calibrated equipment.
Type: HT 7012 S2
Condition: used
Scope of delivery: (see picture)
(Specifications and data subject to change and errors excepted!)
We are happy to answer further questions by phone.
Skelbimas verčiamas automatiškai, todėl jame gali būtų vertimo klaidų.
Water-cooled temperature shock test chamber
Two-chamber design
Hot Chamber:
Temperature range of the hot chamber: +50°C to +220°C
Cedpfx Aaji Az Ego Ssrh
Temporal temperature deviation at the center of the usable space: ±1 K
Spatial temperature deviation: ±2 K
Temperature change rate:
Heating: 11 K/min
Cold Chamber:
Temperature range of the cold chamber: -65°C to +70°C
Temporal temperature deviation at the center of the usable space: ±1 K
Spatial temperature deviation: ±2 K
Temperature change rate:
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Temperature range hot chamber: +50°C to +220°C
Temperature range cold chamber: -80°C to +70°C
Test area dimensions: Width 470mm x Depth 650mm x Height 410mm
External dimensions: Width 930mm x Depth 2115mm x Height 1970+mm
Nominal power: 10 kW
Rated current: 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerants: R404A / R23
Operating hours: 27,903 h
Weight: 1,000 kg
For your safety as a buyer, please note the following information!
The following work is carried out on all test chambers we offer prior to sale:
1. Functional test and replacement of necessary components
2. New filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a test run, which is monitored using calibrated equipment.
Type: HT 7012 S2
Condition: used
Scope of delivery: (see picture)
(Specifications and data subject to change and errors excepted!)
We are happy to answer further questions by phone.
Skelbimas verčiamas automatiškai, todėl jame gali būtų vertimo klaidų.
Tiekėjas
Pastaba: Užsiregistruokite nemokamai arba prisijunkite, kad gautumėte visą informaciją.
Pateikti užklausą
Telefonas & Faksas
+49 2861 ... skelbimai
Šie skelbimai taip pat gali jus sudominti.
mažas skelbimas

1 181 km
Smūgio bandymo kamera
HeraeusHT 7012 S2
HeraeusHT 7012 S2
Jūsų skelbimas sėkmingai pašalintas
Įvyko klaida