Impulsų generatorius izoliacijos testuiGBS Elektronik
rev3 Isolationstests bis 6nF
Impulsų generatorius izoliacijos testui
GBS Elektronik
rev3 Isolationstests bis 6nF
Pradinė kaina neįskaitant PVM
3 780 €
Sąlyga
Naudotas
Vieta
Borken 

Rodyti vaizdus
Rodyti žemėlapį
Duomenys apie mašiną
- Įrenginio aprašas:
- Impulsų generatorius izoliacijos testui
- Gamintojas:
- GBS Elektronik
- Modelis:
- rev3 Isolationstests bis 6nF
- Sąlyga:
- beveik kaip naujas (naudotas)
Kaina ir vieta
Pradinė kaina neįskaitant PVM
3 780 €
- Vieta:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

Skambinti
Pasiūlymo informacija
- Sąrašo ID:
- A17569468
- Nuorodos Nr.:
- 21007
- Naujinta paskutinį kartą:
- Data 2025.08.05
Aprašymas
GBS Test Pulse rev3 Pulse Generator for Long-Term Insulation Testing
The Test Pulse setup is designed for long-duration insulation testing of test specimens with up to 6 nF capacitance.
Psdpfju Egz Rjx Afwerd
Converter for High-Voltage Test Transformer
· Internal sine wave generator: 50–200 Hz.
· Pulse width modulation of the sine signal at 16–24 kHz via full-bridge.
· Converter voltage adjustable from 0–600 V, Imax = 2.6 A, max. output power 1.3 kW
· Pulse current limitation at 110 A (cut-off threshold)
Pulse Transformer – Control
· Control via full-bridge
· Full-bridge power supply adjustable from 0–1000 V, max. 1.3 A
· Pulse current limitation at 100 A (cut-off threshold)
· Pulse width 20–120 μs, nominal 94 μs, adjustable
· 2 selectable series inductances: 150 μH, 300 μH, to adjust the pulse width and rise times to the load capacitance and voltage
· Pulse repetition rate 0.1–2.5 kHz, adjustable
· Polarity: selectable positive, negative, or alternating, depending on the polarity of the sine signal
· Cosine-shaped pulse at the transformer output
Pulse Transformer Cascade
· Output transformers in 5-stage cascaded configuration
· Overall transformation ratio selectable via taps: 1:7.7, 1:10, or 1:15
· Maximum output voltage 15 kV with possible load capacitances of: 6 nF at a pulse width of 73 μs and a repetition rate of 2.5 kHz, 10 nF at a pulse width of 103 μs and a repetition rate of 1.25 kHz
· Voltage divider 1:1000 in parallel
· Overvoltage limitation at approx. 20–23 kV via parallel spark gaps
· Thermistor for overtemperature detection in the first transformer stage
· Ground-side current measurement socket 100 mV/A
Short-Circuit Detection, Testing
· If the maximum bridge currents for transformer drive or the maximum currents of the full-bridge power supplies are exceeded, the high voltage is switched off
· The device features a resettable hour meter to track testing duration
Manufacturer price approx. €59,500
More items—new and used—can be found in our shop!
International shipping costs on request!
Skelbimas verčiamas automatiškai, todėl jame gali būtų vertimo klaidų.
The Test Pulse setup is designed for long-duration insulation testing of test specimens with up to 6 nF capacitance.
Psdpfju Egz Rjx Afwerd
Converter for High-Voltage Test Transformer
· Internal sine wave generator: 50–200 Hz.
· Pulse width modulation of the sine signal at 16–24 kHz via full-bridge.
· Converter voltage adjustable from 0–600 V, Imax = 2.6 A, max. output power 1.3 kW
· Pulse current limitation at 110 A (cut-off threshold)
Pulse Transformer – Control
· Control via full-bridge
· Full-bridge power supply adjustable from 0–1000 V, max. 1.3 A
· Pulse current limitation at 100 A (cut-off threshold)
· Pulse width 20–120 μs, nominal 94 μs, adjustable
· 2 selectable series inductances: 150 μH, 300 μH, to adjust the pulse width and rise times to the load capacitance and voltage
· Pulse repetition rate 0.1–2.5 kHz, adjustable
· Polarity: selectable positive, negative, or alternating, depending on the polarity of the sine signal
· Cosine-shaped pulse at the transformer output
Pulse Transformer Cascade
· Output transformers in 5-stage cascaded configuration
· Overall transformation ratio selectable via taps: 1:7.7, 1:10, or 1:15
· Maximum output voltage 15 kV with possible load capacitances of: 6 nF at a pulse width of 73 μs and a repetition rate of 2.5 kHz, 10 nF at a pulse width of 103 μs and a repetition rate of 1.25 kHz
· Voltage divider 1:1000 in parallel
· Overvoltage limitation at approx. 20–23 kV via parallel spark gaps
· Thermistor for overtemperature detection in the first transformer stage
· Ground-side current measurement socket 100 mV/A
Short-Circuit Detection, Testing
· If the maximum bridge currents for transformer drive or the maximum currents of the full-bridge power supplies are exceeded, the high voltage is switched off
· The device features a resettable hour meter to track testing duration
Manufacturer price approx. €59,500
More items—new and used—can be found in our shop!
International shipping costs on request!
Skelbimas verčiamas automatiškai, todėl jame gali būtų vertimo klaidų.
Tiekėjas
Pastaba: Užsiregistruokite nemokamai arba prisijunkite, kad gautumėte visą informaciją.
Pateikti užklausą
Telefonas & Faksas
+49 2862 ... skelbimai
Jūsų skelbimas sėkmingai pašalintas
Įvyko klaida