Temperatūros bandymo kamera Įėjimo bandymo sistemaCTS
TW-60/9 -60°C bis +100°C 9m³
Temperatūros bandymo kamera Įėjimo bandymo sistema
CTS
TW-60/9 -60°C bis +100°C 9m³
Būklė
Naudotas
Vieta
Borken 

Duomenys apie mašiną
- Mašinos pavadinimas:
- Temperatūros bandymo kamera Įėjimo bandymo sistema
- Gamintojas:
- CTS
- modelis:
- TW-60/9 -60°C bis +100°C 9m³
- Būklė:
- labai geros būklės (naudotas)
Kaina ir vieta
- Vieta:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Skambinti
Pasiūlymo informacija
- Skelbimo ID:
- A17884171
- Nuorodos numeris:
- 24464
- Atnaujinimas:
- paskutinį kartą atnaujinta 12.03.2026
aprašymas
CTS
Model: TW-60/9
Water-cooled Temperature Test Chamber
CTS Temperature Test Chamber, Model TW-60/9
T stands for: Temperature
W stands for: Walk-in
-60 stands for: minimum temperature -60°C
9 stands for: 9 m³ test chamber volume
Technical specification:
Cooling unit:
- Water-cooled, low-noise, semi-hermetic
- Stepless capacity control via electronic monitoring and control system
- Environmentally friendly refrigerant R23 / R404 A
Control:
- 32-bit controller
- LCD control panel
- Digital display of set and actual values
- Numerical input of setpoints
- Error messages in plain text
- RS 232 interface
- Free switching channels for customer-side test item control
Technical performance data:
Temperature testing:
- Temperature range: -60 °C to +100 °C
- Temperature deviation: ± 0.1 to 0.5 K over time
- Average temperature change rate, measured with test item and heat input, at air supply:
- Heating: 1.6 K/min from -40°C to +85°C
- Cooling: 1.6 K/min from +85°C to -40°C
- Test item: 420 kg solar cell modules, 100% loaded
- Heat input: 3000 watts continuous
Technical data based on ambient temperature +25 °C, rated voltage 400 V, without test item, without heat input, and without additional equipment.
Dimensions:
- Test volume: 9 m³
- External dimensions: width approx. 4140 mm, depth 2680 mm, height 3000 mm
- Test chamber inner dimensions: width approx. 1600 mm, depth 2400 mm, height 2200 mm
Operating data:
- Electrical connection: 400 V +6/-10%, 3/N, PE, 50 Hz
- Rated power: 48.9 kW
- Rated current: 74.9 A
Nodpsvb Hanjfx Afxjwg
- Protection class: IP54
- Cooling water connections: cooling water supply/return R1 ¼” internal thread
- Condensate drain: non-pressurized, R1” internal thread
- Weight: approx. 5609 kg
Condition: used
Scope of delivery: (see picture)
(Specifications are subject to change and error!)
We are happy to answer further questions by phone.
Skelbimas buvo automatiškai išverstas. Galimos vertimo klaidos.
Model: TW-60/9
Water-cooled Temperature Test Chamber
CTS Temperature Test Chamber, Model TW-60/9
T stands for: Temperature
W stands for: Walk-in
-60 stands for: minimum temperature -60°C
9 stands for: 9 m³ test chamber volume
Technical specification:
Cooling unit:
- Water-cooled, low-noise, semi-hermetic
- Stepless capacity control via electronic monitoring and control system
- Environmentally friendly refrigerant R23 / R404 A
Control:
- 32-bit controller
- LCD control panel
- Digital display of set and actual values
- Numerical input of setpoints
- Error messages in plain text
- RS 232 interface
- Free switching channels for customer-side test item control
Technical performance data:
Temperature testing:
- Temperature range: -60 °C to +100 °C
- Temperature deviation: ± 0.1 to 0.5 K over time
- Average temperature change rate, measured with test item and heat input, at air supply:
- Heating: 1.6 K/min from -40°C to +85°C
- Cooling: 1.6 K/min from +85°C to -40°C
- Test item: 420 kg solar cell modules, 100% loaded
- Heat input: 3000 watts continuous
Technical data based on ambient temperature +25 °C, rated voltage 400 V, without test item, without heat input, and without additional equipment.
Dimensions:
- Test volume: 9 m³
- External dimensions: width approx. 4140 mm, depth 2680 mm, height 3000 mm
- Test chamber inner dimensions: width approx. 1600 mm, depth 2400 mm, height 2200 mm
Operating data:
- Electrical connection: 400 V +6/-10%, 3/N, PE, 50 Hz
- Rated power: 48.9 kW
- Rated current: 74.9 A
Nodpsvb Hanjfx Afxjwg
- Protection class: IP54
- Cooling water connections: cooling water supply/return R1 ¼” internal thread
- Condensate drain: non-pressurized, R1” internal thread
- Weight: approx. 5609 kg
Condition: used
Scope of delivery: (see picture)
(Specifications are subject to change and error!)
We are happy to answer further questions by phone.
Skelbimas buvo automatiškai išverstas. Galimos vertimo klaidos.
Siųsti užklausą
Telefonas & Faksas
+49 2861 ... skelbimai
Šie skelbimai taip pat gali jus sudominti.
Mažas skelbimas
Borken
1 181 km
Temperatūros bandymo kamera Įėjimo bandymo sistema
CTSTW-60/9 -60°C bis +100°C 9m³
CTSTW-60/9 -60°C bis +100°C 9m³
Mažas skelbimas
Pleystein
991 km
Stiklo šlifavimo staklės
KnoppGlaskant 2-02
KnoppGlaskant 2-02
Mažas skelbimas
Pleystein
991 km
Stiklo plovimo mašina
TriulziGlaswaschmaschine
TriulziGlaswaschmaschine
Mažas skelbimas
Aschersleben
902 km
Dvigubos galvutės stiklo gręžimo staklės
KnoppDuplex 2-20
KnoppDuplex 2-20
Mažas skelbimas
Sofia
1 389 km
Automatinė iškirtimo mašina
LUMMY-1320
LUMMY-1320
Mažas skelbimas
Vokietija
999 km
CNC profilių apdirbimo centras
TeknaTK 426/3
TeknaTK 426/3
Mažas skelbimas
Borken
1 181 km
Įeinama klimato kamera su drėgmės palaikymu
RS-SimulatorenKKM 40/45S
RS-SimulatorenKKM 40/45S
Mažas skelbimas
Weiterstadt
1 185 km
"Knopp" stiklo kraštų šlifavimo staklės
KnoppTyp 2-01
KnoppTyp 2-01
Mažas skelbimas
Vokietija
999 km
Gręžimo ir frezavimo staklės
BotteroDiscovery 770 DMW
BotteroDiscovery 770 DMW
Mažas skelbimas
Plettenberg
1 149 km
Ekscentrinis presas - viena kolona
KIESERLINGPEDRU 100
KIESERLINGPEDRU 100
Jūsų skelbimas sėkmingai pašalintas
Įvyko klaida