Klimato bandymų spinta su drėgme, 600 litrųCTS
C-40/600 -40 bis +180°C
Klimato bandymų spinta su drėgme, 600 litrų
CTS
C-40/600 -40 bis +180°C
Sąlyga
Naudotas
Vieta
Borken 

Rodyti vaizdus
Rodyti žemėlapį
Duomenys apie mašiną
- Įrenginio aprašas:
- Klimato bandymų spinta su drėgme, 600 litrų
- Gamintojas:
- CTS
- Modelis:
- C-40/600 -40 bis +180°C
- Sąlyga:
- labai geros būklės (naudotas)
Kaina ir vieta
- Vieta:
- Einsteinstraße 8a, 46325 Borken, DE
Skambinti
Pasiūlymo informacija
- Sąrašo ID:
- A19913290
- Nuorodos Nr.:
- 24786
- Naujinta paskutinį kartą:
- Data 2025.09.03
Aprašymas
CTS Climate Test Chamber Type: C -40/600 Air-Cooled
(converted to R-452A refrigerant)
Test chamber volume: 600 liters
Temperature testing:
- Temperature range: -40°C to +180°C
- Temperature deviation: ±0.1 K / ±0.3 K (over time, in steady-state conditions)
- Average temperature change rate (without test specimen and without radiant heat):
Heating: 2.5 K/min
Cooling: 3.0 K/min
- Radiant heat max. 2500 W at +20°C
Climate testing:
Climate range / Technical data:
- Temperature range: +10°C to +95°C
- Humidity range: 10% r.h. to 98% r.h.
- Dew point range I: +7°C to +94°C
- Dew point range II: –10°C to +7°C
- Consistency values (over time):
Humidity consistency I: ±0.5% r.h. to ±1.5% r.h.
Humidity consistency II: ±1% r.h. to ±3% r.h.
Temperature consistency: ±0.1 K to ±0.3 K
Test chamber internal dimensions (approx.): Height 850 mm, Width 850 mm, Depth 830 mm
External dimensions (approx.): Height 1900 mm, Width 1115 mm, Depth 1850 mm
Refrigerant: R-452A
Electrical connection: 400V 3/N 50Hz
Djdpew U Awmofx Af Hjwc
Connected load: 8.2 kW, Rated current: 11.9 A
Weight: 550 kg
Important information for buyers! For your safety, the following procedures are carried out in advance on our chambers on offer:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant if necessary
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (See picture)
(Subject to change and errors in technical data and specifications!)
For further questions, please feel free to contact us by phone.
Skelbimas verčiamas automatiškai, todėl jame gali būtų vertimo klaidų.
(converted to R-452A refrigerant)
Test chamber volume: 600 liters
Temperature testing:
- Temperature range: -40°C to +180°C
- Temperature deviation: ±0.1 K / ±0.3 K (over time, in steady-state conditions)
- Average temperature change rate (without test specimen and without radiant heat):
Heating: 2.5 K/min
Cooling: 3.0 K/min
- Radiant heat max. 2500 W at +20°C
Climate testing:
Climate range / Technical data:
- Temperature range: +10°C to +95°C
- Humidity range: 10% r.h. to 98% r.h.
- Dew point range I: +7°C to +94°C
- Dew point range II: –10°C to +7°C
- Consistency values (over time):
Humidity consistency I: ±0.5% r.h. to ±1.5% r.h.
Humidity consistency II: ±1% r.h. to ±3% r.h.
Temperature consistency: ±0.1 K to ±0.3 K
Test chamber internal dimensions (approx.): Height 850 mm, Width 850 mm, Depth 830 mm
External dimensions (approx.): Height 1900 mm, Width 1115 mm, Depth 1850 mm
Refrigerant: R-452A
Electrical connection: 400V 3/N 50Hz
Djdpew U Awmofx Af Hjwc
Connected load: 8.2 kW, Rated current: 11.9 A
Weight: 550 kg
Important information for buyers! For your safety, the following procedures are carried out in advance on our chambers on offer:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant if necessary
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (See picture)
(Subject to change and errors in technical data and specifications!)
For further questions, please feel free to contact us by phone.
Skelbimas verčiamas automatiškai, todėl jame gali būtų vertimo klaidų.
Tiekėjas
Pastaba: Užsiregistruokite nemokamai arba prisijunkite, kad gautumėte visą informaciją.
Pateikti užklausą
Telefonas & Faksas
+49 2861 ... skelbimai
Jūsų skelbimas sėkmingai pašalintas
Įvyko klaida