Type: WKL 100/40
Climate Test Chamber, Air-Cooled
with Humidity Control, -40 to +180°C
Specifications for Temperature Tests:
Temperature Range: -40 to +180°C
Temperature Variations at Steady State:
Temporal Temperature Fluctuation at Chamber Center: ±0.3 to ±1 K
Spatial Temperature Deviation: ±0.5 to ±2 K
Temperature Change Rate:
Heating: 3.5 K/min
Cooling: 5 K/min
Maximum Heat Compensation: 1100 W
Specifications for Climate Tests:
Humidification System Data:
Reservoir Capacity: approx. 13 liters
Water Quality: Demineralized
pH Value: 6 – 7
Conductivity: max. 20 μS/cm
Water Consumption at Constant Temperature (+40°C, 92% RH): 2 l / 24 h
Temperature Range: +10 to +95°C
Humidity Range: 10 to 98 % RH
Temperature and Humidity Variations (at steady state):
Temporal Temperature Fluctuation at Chamber Center: ±0.3 to ±0.5 K
Spatial Temperature Deviation: ±0.5 to ±1.5 K
Temporal Humidity Fluctuation at Chamber Center: ±1 to ±3 % RH
Mechanical Stress Data:
Maximum Load on Test Chamber Floor: 25 kg
Per Shelf: 10 kg
Total Shelf Support Load: 50 kg
Port: 50 mm Ø
Interfaces:
Ethernet Interface (RJ45), USB Interface
Dksdpfoxhf Erex Af Hju
Operational Data:
Chamber Lighting: Halogen Bulb 24V, 50W
Rated Voltage: 1/N / PE AC 230 V ±10% 50 Hz
Rated Power: 3.0 kW
Rated Current: 13.0 A
Fuse (on-site): 16A slow-blow
Protection Class:
Control Cabinet IP 22 and Control Panel IP 54
Heat Emission for Air-Cooled Chambers:
Maximum Heat Emission to Ambient: 2000 W
Noise Measurement:
Sound Pressure Level (Free-field measurement, 1 m distance from front at 1.6 m height): approx. 56 dB(A)
Chamber Volume: approx. 100 liters
Weight: 190 kg
Refrigerant: R404A
Important Safety Information for Buyers!
The following procedures are carried out on all chambers offered by us beforehand:
1. Functional check and replacement of necessary components
2. Recharging with legally compliant refrigerant if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Technical data and specifications are subject to change and errors!)
For further questions, we are happy to assist you by phone.
Skelbimas verčiamas automatiškai, todėl jame gali būtų vertimo klaidų.
Climate Test Chamber, Air-Cooled
with Humidity Control, -40 to +180°C
Specifications for Temperature Tests:
Temperature Range: -40 to +180°C
Temperature Variations at Steady State:
Temporal Temperature Fluctuation at Chamber Center: ±0.3 to ±1 K
Spatial Temperature Deviation: ±0.5 to ±2 K
Temperature Change Rate:
Heating: 3.5 K/min
Cooling: 5 K/min
Maximum Heat Compensation: 1100 W
Specifications for Climate Tests:
Humidification System Data:
Reservoir Capacity: approx. 13 liters
Water Quality: Demineralized
pH Value: 6 – 7
Conductivity: max. 20 μS/cm
Water Consumption at Constant Temperature (+40°C, 92% RH): 2 l / 24 h
Temperature Range: +10 to +95°C
Humidity Range: 10 to 98 % RH
Temperature and Humidity Variations (at steady state):
Temporal Temperature Fluctuation at Chamber Center: ±0.3 to ±0.5 K
Spatial Temperature Deviation: ±0.5 to ±1.5 K
Temporal Humidity Fluctuation at Chamber Center: ±1 to ±3 % RH
Mechanical Stress Data:
Maximum Load on Test Chamber Floor: 25 kg
Per Shelf: 10 kg
Total Shelf Support Load: 50 kg
Port: 50 mm Ø
Interfaces:
Ethernet Interface (RJ45), USB Interface
Dksdpfoxhf Erex Af Hju
Operational Data:
Chamber Lighting: Halogen Bulb 24V, 50W
Rated Voltage: 1/N / PE AC 230 V ±10% 50 Hz
Rated Power: 3.0 kW
Rated Current: 13.0 A
Fuse (on-site): 16A slow-blow
Protection Class:
Control Cabinet IP 22 and Control Panel IP 54
Heat Emission for Air-Cooled Chambers:
Maximum Heat Emission to Ambient: 2000 W
Noise Measurement:
Sound Pressure Level (Free-field measurement, 1 m distance from front at 1.6 m height): approx. 56 dB(A)
Chamber Volume: approx. 100 liters
Weight: 190 kg
Refrigerant: R404A
Important Safety Information for Buyers!
The following procedures are carried out on all chambers offered by us beforehand:
1. Functional check and replacement of necessary components
2. Recharging with legally compliant refrigerant if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Technical data and specifications are subject to change and errors!)
For further questions, we are happy to assist you by phone.
Skelbimas verčiamas automatiškai, todėl jame gali būtų vertimo klaidų.
Tiekėjas
Pastaba: Užsiregistruokite nemokamai arba prisijunkite, kad gautumėte visą informaciją.
Pateikti užklausą
Telefonas & Faksas
+49 2861 ... skelbimai
Jūsų skelbimas sėkmingai pašalintas
Įvyko klaida