600 litrų klimato bandymo kamera su drėgmės palaikymuWeiss
WK3-600/0-M -5°C bis +90°C
600 litrų klimato bandymo kamera su drėgmės palaikymu
Weiss
WK3-600/0-M -5°C bis +90°C
Būklė
Naudotas
Vieta
Borken 

Duomenys apie mašiną
- Mašinos pavadinimas:
- 600 litrų klimato bandymo kamera su drėgmės palaikymu
- Gamintojas:
- Weiss
- modelis:
- WK3-600/0-M -5°C bis +90°C
- Būklė:
- labai geros būklės (naudotas)
Kaina ir vieta
- Vieta:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Skambinti
Pasiūlymo informacija
- Skelbimo ID:
- A22270542
- Nuorodos numeris:
- 24892
- Atnaujinimas:
- paskutinį kartą atnaujinta 06.07.2026
aprašymas
Weiss
Model: WK3 600/0-M
Weiss Climate Test Chamber, Water-Cooled
Series: WK3-../0
with SIMPAC* Control
Test Chamber Volume: approx. 600 liters
Test Chamber Dimensions: Height 950 mm, Width 800 mm, Depth 800 mm
External Dimensions: Height 1995 mm, Width 1090 mm, Depth 1660 mm
Operating Data:
Test Chamber Lighting: LED 24 V, 6.8 W / Halogen Bulb 2 x 24V, 50W
Rated Voltage: 1/N / PE AC 230 V ±10% 50 Hz
Rated Power: 2.3 kW
Rated Current: 10 A
Required Fuse: 16 A slow-blow
Protection Class (Control Cabinet and Operator Panel): IP 54
Maximum Heat Emission to Ambient: 1200 W
Sound Pressure Level: approx. 46 dB(A) (measured at 1 m distance from the front, 1.6 m height)
Data for Temperature Tests:
Temperature Range: -5°C to +90°C
Cjdpfxoziywro Ab Rsgw
Temporal Temperature Deviation (center of usable space): ± 0.1 to ± 0.5 K
Spatial Temperature Deviation: ± 0.5 to ± 1 K
Temperature Gradient (per IEC 60068-3-5)
Temperature Change Rate: Heating 0.6 K/min, Cooling 0.3 K/min
Heat Compensation at +20°C to +50°C: 200 W
Data for Climatic Tests:
Temperature Range: +10°C to +90°C
Dew Point Range: 4 to +89.5°C
Humidity Range: 10 to 98 % RH
Temporal Temperature Deviation (center of usable space): ± 0.1 to ± 0.3 K
Spatial Temperature Deviation: ± 0.5 to ± 1 K
Temporal Humidity Deviation: +1 to +3 % RH
Refrigerant: R-404A
Weight: 610 kg
Important Information for Your Safety as a Buyer!
The following processes are carried out on all chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. Refilled with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, monitored with calibrated devices.
Condition: Used
Scope of delivery: (See image)
(Technical data subject to change and errors excepted!)
Please feel free to contact us by phone with any further questions.
Skelbimas buvo automatiškai išverstas. Galimos vertimo klaidos.
Model: WK3 600/0-M
Weiss Climate Test Chamber, Water-Cooled
Series: WK3-../0
with SIMPAC* Control
Test Chamber Volume: approx. 600 liters
Test Chamber Dimensions: Height 950 mm, Width 800 mm, Depth 800 mm
External Dimensions: Height 1995 mm, Width 1090 mm, Depth 1660 mm
Operating Data:
Test Chamber Lighting: LED 24 V, 6.8 W / Halogen Bulb 2 x 24V, 50W
Rated Voltage: 1/N / PE AC 230 V ±10% 50 Hz
Rated Power: 2.3 kW
Rated Current: 10 A
Required Fuse: 16 A slow-blow
Protection Class (Control Cabinet and Operator Panel): IP 54
Maximum Heat Emission to Ambient: 1200 W
Sound Pressure Level: approx. 46 dB(A) (measured at 1 m distance from the front, 1.6 m height)
Data for Temperature Tests:
Temperature Range: -5°C to +90°C
Cjdpfxoziywro Ab Rsgw
Temporal Temperature Deviation (center of usable space): ± 0.1 to ± 0.5 K
Spatial Temperature Deviation: ± 0.5 to ± 1 K
Temperature Gradient (per IEC 60068-3-5)
Temperature Change Rate: Heating 0.6 K/min, Cooling 0.3 K/min
Heat Compensation at +20°C to +50°C: 200 W
Data for Climatic Tests:
Temperature Range: +10°C to +90°C
Dew Point Range: 4 to +89.5°C
Humidity Range: 10 to 98 % RH
Temporal Temperature Deviation (center of usable space): ± 0.1 to ± 0.3 K
Spatial Temperature Deviation: ± 0.5 to ± 1 K
Temporal Humidity Deviation: +1 to +3 % RH
Refrigerant: R-404A
Weight: 610 kg
Important Information for Your Safety as a Buyer!
The following processes are carried out on all chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. Refilled with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, monitored with calibrated devices.
Condition: Used
Scope of delivery: (See image)
(Technical data subject to change and errors excepted!)
Please feel free to contact us by phone with any further questions.