Type: WK3-340/70
Weiss Climate Test Chamber, Water Cooled
Control Unit: "Touch Panel"
All control and operating commands can be executed on the control unit via simple touch of the function symbols.
Adjustable Feet
To compensate for floor unevenness and ensure adequate ventilation of the machine section, the test chamber is equipped with adjustable feet.
Feedthroughs
The test chamber features feedthroughs on both the right and left sides. These allow measuring cables and test devices to be routed into the test chamber interior.
Feedthroughs included in standard equipment:
R1: nominal width 125 mm
L1: nominal width 85 mm
Volume: 335 liters
Test Chamber Dimensions:
Internal dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Specifications for Temperature Tests:
Minimum temperature: –72°C
Maximum temperature: +180°C
Temporal temperature deviation: ± 0.1 to ± 0.5 K
Spatial temperature uniformity: ± 0.5 to ± 1.5 K
Temperature change rate, cooling: 3 K/min
Temperature change rate, heating: 3 K/min
Specifications for Climatic Tests:
Temperature range: +10°C to +95°C
Dew point range: -3°C to +94°C
Humidity range: 10 to 98% r.h.
Temporal temperature deviation: ± 0.1 to ± 0.3 K
Spatial temperature uniformity: ± 0.5 to ± 1 K
Temporal humidity deviation: ± 1 to ± 3% r.h.
Operating Data:
Test chamber illumination: Halogen bulb 2 x 24V, 50W
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 16 A;
Rated power: 4.9 kW
Customer-side fuse: 16 A slow-blow
Refrigerant: R-452A/R23
Weight: approx. 585 kg
Godpfx Aexmg Sdocusbu
Important safety information for buyers:
The following steps are carried out on each of our chambers prior to sale:
1. Functional inspection and replacement of necessary components
2. New filling with legally compliant refrigerant if required
3. Leak test with certificate
4. After successful inspection, each chamber undergoes a documented trial run.
Condition: Used
Scope of delivery: (see picture)
(Specifications and technical data subject to change and errors!)
If you have any further questions, we will be happy to answer them by phone.
Skelbimas verčiamas automatiškai, todėl jame gali būtų vertimo klaidų.
Weiss Climate Test Chamber, Water Cooled
Control Unit: "Touch Panel"
All control and operating commands can be executed on the control unit via simple touch of the function symbols.
Adjustable Feet
To compensate for floor unevenness and ensure adequate ventilation of the machine section, the test chamber is equipped with adjustable feet.
Feedthroughs
The test chamber features feedthroughs on both the right and left sides. These allow measuring cables and test devices to be routed into the test chamber interior.
Feedthroughs included in standard equipment:
R1: nominal width 125 mm
L1: nominal width 85 mm
Volume: 335 liters
Test Chamber Dimensions:
Internal dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Specifications for Temperature Tests:
Minimum temperature: –72°C
Maximum temperature: +180°C
Temporal temperature deviation: ± 0.1 to ± 0.5 K
Spatial temperature uniformity: ± 0.5 to ± 1.5 K
Temperature change rate, cooling: 3 K/min
Temperature change rate, heating: 3 K/min
Specifications for Climatic Tests:
Temperature range: +10°C to +95°C
Dew point range: -3°C to +94°C
Humidity range: 10 to 98% r.h.
Temporal temperature deviation: ± 0.1 to ± 0.3 K
Spatial temperature uniformity: ± 0.5 to ± 1 K
Temporal humidity deviation: ± 1 to ± 3% r.h.
Operating Data:
Test chamber illumination: Halogen bulb 2 x 24V, 50W
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 16 A;
Rated power: 4.9 kW
Customer-side fuse: 16 A slow-blow
Refrigerant: R-452A/R23
Weight: approx. 585 kg
Godpfx Aexmg Sdocusbu
Important safety information for buyers:
The following steps are carried out on each of our chambers prior to sale:
1. Functional inspection and replacement of necessary components
2. New filling with legally compliant refrigerant if required
3. Leak test with certificate
4. After successful inspection, each chamber undergoes a documented trial run.
Condition: Used
Scope of delivery: (see picture)
(Specifications and technical data subject to change and errors!)
If you have any further questions, we will be happy to answer them by phone.
Skelbimas verčiamas automatiškai, todėl jame gali būtų vertimo klaidų.
Tiekėjas
Pastaba: Užsiregistruokite nemokamai arba prisijunkite, kad gautumėte visą informaciją.
Pateikti užklausą
Telefonas & Faksas
+49 2861 ... skelbimai
Jūsų skelbimas sėkmingai pašalintas
Įvyko klaida