Klimato kamera su drėgmės valdymu, nuo -70°C iki 180°CWeiss
WK11-600/70/5
Klimato kamera su drėgmės valdymu, nuo -70°C iki 180°C
Weiss
WK11-600/70/5
Būklė
Naudotas
Vieta
Borken 

Rodyti nuotraukas
Rodyti žemėlapį
Duomenys apie mašiną
- Mašinos pavadinimas:
- Klimato kamera su drėgmės valdymu, nuo -70°C iki 180°C
- Gamintojas:
- Weiss
- modelis:
- WK11-600/70/5
- Būklė:
- labai geros būklės (naudotas)
Kaina ir vieta
- Vieta:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Skambinti
Pasiūlymo informacija
- Skelbimo ID:
- A21144637
- Nuorodos numeris:
- 25022
- Atnaujinimas:
- paskutinį kartą atnaujinta 02.02.2026
aprašymas
Weiss
Type: WK11 - 600/70/5
Weiss Climate Chamber, Water-cooled
The Weiss Climate Chamber WK11-600/70/5, with an approximate usable volume of 600 liters, is suitable for temperature and humidity testing as well as conditioning of samples and materials within a range of −70 °C to +180 °C.
Simcon/32 - Net control system
Technical Data:
Chamber designation: WK11-600/70/5
External dimensions with hinges and door lock:
Height: 1995 mm, Width: 1090 mm, Depth: 1660 mm
External dimensions without hinges and door lock:
Height: 1995 mm, Width: 1000 mm, Depth: 800 mm
Internal dimensions:
Height: 950 mm, Width: 800 mm, Depth: 800 mm
Feedthroughs:
2x R1 NW 125 mm ∅
1x L1 NW 50 mm ∅
Test chamber volume: approx. 600 liters
Specifications for temperature tests:
Temperature range: -70 °C to 180°C
Temperature deviation over time at chamber center: ± 0.1 to ± 0.5 K
Temperature deviation spatially: ± 0.5 to ± 2 K
Temperature gradient: 1 to 4 K
Temperature change rate:
Heating: 6 K/min
Cooling: 6 K/min
Heat compensation:
at +20 °C: 5000 W
at -20 °C: 5000 W
Specifications for climate tests:
Temperature range: +10 to +95 °C
Humidity range: 10 to 98% r.h.
Temperature deviation over time at chamber center: ± 0.1 to ± 0.3 K
Fgsdpfxeyglb Sj Ac Doa
Temperature deviation spatially: ± 0.5 to ± 1 K
Temperature gradient: 1 to 2 K
Humidity fluctuation over time at chamber center: ± 1 to ± 3% r.h.
Heat compensation: 500 W
Power supply: 3/N/PE AC 400V ±10% 50Hz
Nominal power: 16.5 kW
Nominal current: 29 A
Required fuse: 32 A slow-blow
Permissible test specimen weight:
Total load on shelf supports: 80 kg
Chamber floor: 80 kg, Shelf insert: 40 kg
Weight: 675 kg
Refrigerant: R452A / R23
Important Note:
"The table shown in the photos is not included in the sale."
For your safety as a buyer, the following procedures are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After a successful check, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Subject to changes and errors in technical data and specifications!)
For further questions, we are happy to assist you by phone.
Skelbimas buvo automatiškai išverstas. Galimos vertimo klaidos.
Type: WK11 - 600/70/5
Weiss Climate Chamber, Water-cooled
The Weiss Climate Chamber WK11-600/70/5, with an approximate usable volume of 600 liters, is suitable for temperature and humidity testing as well as conditioning of samples and materials within a range of −70 °C to +180 °C.
Simcon/32 - Net control system
Technical Data:
Chamber designation: WK11-600/70/5
External dimensions with hinges and door lock:
Height: 1995 mm, Width: 1090 mm, Depth: 1660 mm
External dimensions without hinges and door lock:
Height: 1995 mm, Width: 1000 mm, Depth: 800 mm
Internal dimensions:
Height: 950 mm, Width: 800 mm, Depth: 800 mm
Feedthroughs:
2x R1 NW 125 mm ∅
1x L1 NW 50 mm ∅
Test chamber volume: approx. 600 liters
Specifications for temperature tests:
Temperature range: -70 °C to 180°C
Temperature deviation over time at chamber center: ± 0.1 to ± 0.5 K
Temperature deviation spatially: ± 0.5 to ± 2 K
Temperature gradient: 1 to 4 K
Temperature change rate:
Heating: 6 K/min
Cooling: 6 K/min
Heat compensation:
at +20 °C: 5000 W
at -20 °C: 5000 W
Specifications for climate tests:
Temperature range: +10 to +95 °C
Humidity range: 10 to 98% r.h.
Temperature deviation over time at chamber center: ± 0.1 to ± 0.3 K
Fgsdpfxeyglb Sj Ac Doa
Temperature deviation spatially: ± 0.5 to ± 1 K
Temperature gradient: 1 to 2 K
Humidity fluctuation over time at chamber center: ± 1 to ± 3% r.h.
Heat compensation: 500 W
Power supply: 3/N/PE AC 400V ±10% 50Hz
Nominal power: 16.5 kW
Nominal current: 29 A
Required fuse: 32 A slow-blow
Permissible test specimen weight:
Total load on shelf supports: 80 kg
Chamber floor: 80 kg, Shelf insert: 40 kg
Weight: 675 kg
Refrigerant: R452A / R23
Important Note:
"The table shown in the photos is not included in the sale."
For your safety as a buyer, the following procedures are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After a successful check, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Subject to changes and errors in technical data and specifications!)
For further questions, we are happy to assist you by phone.
Skelbimas buvo automatiškai išverstas. Galimos vertimo klaidos.
Siųsti užklausą
Telefonas & Faksas
+49 2861 ... skelbimai
Šie skelbimai taip pat gali jus sudominti.
Mažas skelbimas
Borken
1 181 km
Klimato spinta 335 litrai
WeissWK-340/70 -70 °C bis +180 °C
WeissWK-340/70 -70 °C bis +180 °C
Jūsų skelbimas sėkmingai pašalintas
Įvyko klaida

























