Didelės talpos klimato bandymų kamera su drėgmeVötsch
VCZ 04032
Didelės talpos klimato bandymų kamera su drėgme
Vötsch
VCZ 04032
VB plius PVM
22 520 €
Būklė
Naudotas
Vieta
Borken 

Rodyti nuotraukas
Rodyti žemėlapį
Duomenys apie mašiną
- Mašinos pavadinimas:
- Didelės talpos klimato bandymų kamera su drėgme
- Gamintojas:
- Vötsch
- modelis:
- VCZ 04032
- Būklė:
- geras (naudotas)
Kaina ir vieta
VB plius PVM
22 520 €
- Vieta:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

Skambinti
Pasiūlymo informacija
- Skelbimo ID:
- A19920440
- Nuorodos numeris:
- 51525
- Atnaujinimas:
- paskutinį kartą atnaujinta 13.02.2026
aprašymas
Large-Scale Climate Testing Facility with S!MCON Control
Construction
The system comprises the following main assemblies:
- Walk-in, insulated test chamber
- Air treatment room
- Machine unit
Iedew U Sv Eopfx Aausar
- Climate control system
- Control cabinet
Test Chamber
The interior fittings in the test chamber are made from corrosion-resistant materials.
The test chamber is walk-in, can be illuminated, and features a condensate drain and cleaning outlet.
Air Treatment Room
The air treatment room is located behind the air duct wall within the insulated interior.
It contains the following assemblies necessary for climate control and can be accessed via easily removable panels:
- Test chamber fans
- Heat exchangers
- Electric heating elements
- Ventilation and exhaust system
- Temperature sensors
In the air treatment room, the air is heated or cooled, humidified or dehumidified, and recirculated by fans.
Air is drawn in at ceiling level and blown out at floor level.
Sensors
Temperature and humidity sensors are located behind the air duct wall in the air treatment room.
Machine Unit
The machine unit, consisting of refrigeration systems, supplies the necessary energy to the air treatment room.
Climate Control System
The climate control system consists of:
- Steam humidifier
- Dehumidification evaporator
Technical Data
Test chamber volume: approx. 32 m³
Direct temperature range: -40 to +100°C
Temperature fluctuation (temporal, center of usable space): +/- 0.5 to +/- 1°C
Temperature change rates
Heating: from -35°C to +50°C at 3 K/min
Cooling: from +85°C to +85°C at 2 K/min
from +80°C to -40°C at 1 K/min
Data for climate testing
Temperature range: 10 to 95°C
Humidity range: 10 to 95% RH
Dew point range: 5 to 93°C
Temperature fluctuation: +/- 5 K
Humidity fluctuation: +/- 3 to +/- 5% RH
Data for cooling water
Connections
Inlet: 2 x R 1 1/2 2"
Outlet: 2 x R 1 1/2 2"
Consumption at full load: max. 16 m³/h
Max. floor load in test chamber: 10,000 N/m²
Nominal voltage: 3/N / PE AC 400 V 50 Hz
Nominal power: 97 kW
Nominal current: 148 A
Dimensions:
Test chamber: Width 3.60 m x Height 2.20 m x Depth 5 m
Climatic chamber is divided for transport to designated location (approx. 2.50 m).
Financing through our bank is also available.
komplett-konzept.leasingo.de
You will find more – new and used – items in our shop!
International shipping costs on request!
Skelbimas buvo automatiškai išverstas. Galimos vertimo klaidos.
Construction
The system comprises the following main assemblies:
- Walk-in, insulated test chamber
- Air treatment room
- Machine unit
Iedew U Sv Eopfx Aausar
- Climate control system
- Control cabinet
Test Chamber
The interior fittings in the test chamber are made from corrosion-resistant materials.
The test chamber is walk-in, can be illuminated, and features a condensate drain and cleaning outlet.
Air Treatment Room
The air treatment room is located behind the air duct wall within the insulated interior.
It contains the following assemblies necessary for climate control and can be accessed via easily removable panels:
- Test chamber fans
- Heat exchangers
- Electric heating elements
- Ventilation and exhaust system
- Temperature sensors
In the air treatment room, the air is heated or cooled, humidified or dehumidified, and recirculated by fans.
Air is drawn in at ceiling level and blown out at floor level.
Sensors
Temperature and humidity sensors are located behind the air duct wall in the air treatment room.
Machine Unit
The machine unit, consisting of refrigeration systems, supplies the necessary energy to the air treatment room.
Climate Control System
The climate control system consists of:
- Steam humidifier
- Dehumidification evaporator
Technical Data
Test chamber volume: approx. 32 m³
Direct temperature range: -40 to +100°C
Temperature fluctuation (temporal, center of usable space): +/- 0.5 to +/- 1°C
Temperature change rates
Heating: from -35°C to +50°C at 3 K/min
Cooling: from +85°C to +85°C at 2 K/min
from +80°C to -40°C at 1 K/min
Data for climate testing
Temperature range: 10 to 95°C
Humidity range: 10 to 95% RH
Dew point range: 5 to 93°C
Temperature fluctuation: +/- 5 K
Humidity fluctuation: +/- 3 to +/- 5% RH
Data for cooling water
Connections
Inlet: 2 x R 1 1/2 2"
Outlet: 2 x R 1 1/2 2"
Consumption at full load: max. 16 m³/h
Max. floor load in test chamber: 10,000 N/m²
Nominal voltage: 3/N / PE AC 400 V 50 Hz
Nominal power: 97 kW
Nominal current: 148 A
Dimensions:
Test chamber: Width 3.60 m x Height 2.20 m x Depth 5 m
Climatic chamber is divided for transport to designated location (approx. 2.50 m).
Financing through our bank is also available.
komplett-konzept.leasingo.de
You will find more – new and used – items in our shop!
International shipping costs on request!