Termošoko bandymo įrenginys –70 iki +240 °CRS-Simulatoren
ST2K320/70D
Termošoko bandymo įrenginys –70 iki +240 °C
RS-Simulatoren
ST2K320/70D
Sąlyga
Naudotas
Vieta
Borken 

Rodyti vaizdus
Rodyti žemėlapį
Duomenys apie mašiną
- Įrenginio aprašas:
- Termošoko bandymo įrenginys –70 iki +240 °C
- Gamintojas:
- RS-Simulatoren
- Modelis:
- ST2K320/70D
- Sąlyga:
- labai geros būklės (naudotas)
Kaina ir vieta
- Vieta:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Skambinti
Pasiūlymo informacija
- Sąrašo ID:
- A19523991
- Nuorodos Nr.:
- 24684
- Naujinta paskutinį kartą:
- Data 2025.07.08
Aprašymas
RS Simulators
RS Simulators ST2K 320/70D
Water-Cooled Shock Test System
For sale is a high-performance thermal shock test system, model ST2K 320/70D.
This unit is ideally suited for standard-compliant thermal shock testing
according to DIN EN 60068‑2‑14, including optional humidity testing in the upper test chamber.
With its two temperature chambers (–70 °C to +240 °C) and automatic test basket transfer,
this unit offers the perfect solution for component, material, and reliability testing
in industry, research, and quality assurance.
Main Technical Specifications:
Temperature Ranges
Upper test chamber: +40 °C to +240 °C
Temporal deviation: ±0.8 K (to DIN 50011, empty chamber)
Lower test chamber: –70 °C to +240 °C
Temporal deviation: ±0.8 K (to DIN 50011, empty chamber)
Humidity test (optional) – Upper test chamber
Temperature: +40 °C to +90 °C
Kedewx Ip Dspfx Afijdw
Humidity: 20 % to 98 % RH (±2–5 %)
Test basket transfer:
Vertical movement, < 10 seconds transfer time
Power supply:
Total power consumption: 16 kVA
Current draw: 32 A
Main fuse: 3× 35 A slow-blow
Mains connection: 3× 400 V / N / PE / 50 Hz
Main supply line: 5× 16 mm²
Water & compressed air connections
Cooling water inlet: G ¾", approx. 3 bar, max. 10 bar / max. 15 °C
Cooling water requirement: max. 1.4 m³/h
Cooling water return: G ¾", max. 25.2 °C
Condensate drain: 2× G ½", 1× G ¼", non-pressurized
Deionized water inlet: G ⅜", approx. 3 bar, max. 6 bar
Compressed air connection: Quick-release coupling NW 7.2 (G ¼"), min. 4 bar, max. 10 bar
Dimensions & Weight:
Test basket internal dimensions (type ST2K 320)
Internal: width approx. 430 mm, height approx. 470 mm, depth approx. 700 mm
External: width approx. 1100 mm, height approx. 2300 mm, depth approx. 2300 mm
Weight: approx. 1150 kg
Other Technical Data
Sound level: approx. 60 dB(A) at 1 m distance (free field)
Refrigerants:
R-404A: approx. 2.5 kg (GWP 3,800, limit value 0.48 kg/m³)
R-23: approx. 0.8 kg (GWP 12,100, limit value 0.68 kg/m³)
Permitted operating environment:
Temperature: +12 °C to +30 °C
Humidity: 25%–75% RH
For your safety as a buyer, please note the following information!
The following points are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful checks, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Specifications subject to change and errors excepted!)
We are happy to answer additional questions by phone.
Skelbimas verčiamas automatiškai, todėl jame gali būtų vertimo klaidų.
RS Simulators ST2K 320/70D
Water-Cooled Shock Test System
For sale is a high-performance thermal shock test system, model ST2K 320/70D.
This unit is ideally suited for standard-compliant thermal shock testing
according to DIN EN 60068‑2‑14, including optional humidity testing in the upper test chamber.
With its two temperature chambers (–70 °C to +240 °C) and automatic test basket transfer,
this unit offers the perfect solution for component, material, and reliability testing
in industry, research, and quality assurance.
Main Technical Specifications:
Temperature Ranges
Upper test chamber: +40 °C to +240 °C
Temporal deviation: ±0.8 K (to DIN 50011, empty chamber)
Lower test chamber: –70 °C to +240 °C
Temporal deviation: ±0.8 K (to DIN 50011, empty chamber)
Humidity test (optional) – Upper test chamber
Temperature: +40 °C to +90 °C
Kedewx Ip Dspfx Afijdw
Humidity: 20 % to 98 % RH (±2–5 %)
Test basket transfer:
Vertical movement, < 10 seconds transfer time
Power supply:
Total power consumption: 16 kVA
Current draw: 32 A
Main fuse: 3× 35 A slow-blow
Mains connection: 3× 400 V / N / PE / 50 Hz
Main supply line: 5× 16 mm²
Water & compressed air connections
Cooling water inlet: G ¾", approx. 3 bar, max. 10 bar / max. 15 °C
Cooling water requirement: max. 1.4 m³/h
Cooling water return: G ¾", max. 25.2 °C
Condensate drain: 2× G ½", 1× G ¼", non-pressurized
Deionized water inlet: G ⅜", approx. 3 bar, max. 6 bar
Compressed air connection: Quick-release coupling NW 7.2 (G ¼"), min. 4 bar, max. 10 bar
Dimensions & Weight:
Test basket internal dimensions (type ST2K 320)
Internal: width approx. 430 mm, height approx. 470 mm, depth approx. 700 mm
External: width approx. 1100 mm, height approx. 2300 mm, depth approx. 2300 mm
Weight: approx. 1150 kg
Other Technical Data
Sound level: approx. 60 dB(A) at 1 m distance (free field)
Refrigerants:
R-404A: approx. 2.5 kg (GWP 3,800, limit value 0.48 kg/m³)
R-23: approx. 0.8 kg (GWP 12,100, limit value 0.68 kg/m³)
Permitted operating environment:
Temperature: +12 °C to +30 °C
Humidity: 25%–75% RH
For your safety as a buyer, please note the following information!
The following points are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful checks, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Specifications subject to change and errors excepted!)
We are happy to answer additional questions by phone.
Skelbimas verčiamas automatiškai, todėl jame gali būtų vertimo klaidų.
Tiekėjas
Pastaba: Užsiregistruokite nemokamai arba prisijunkite, kad gautumėte visą informaciją.
Registruota nuo: 2012
Pateikti užklausą
Telefonas & Faksas
+49 2861 ... skelbimai