Diferencinis skenuojantis kalorimetrasPerkin Elmer
DSC 8000, N5340524
Diferencinis skenuojantis kalorimetras
Perkin Elmer
DSC 8000, N5340524
EXW Fiksuota kaina plius PVM
29 750 €
Būklė
Naudotas
Vieta
Dresden 

Rodyti nuotraukas
Rodyti žemėlapį
Duomenys apie mašiną
- Mašinos pavadinimas:
- Diferencinis skenuojantis kalorimetras
- Gamintojas:
- Perkin Elmer
- modelis:
- DSC 8000, N5340524
- Būklė:
- naudotas
Kaina ir vieta
EXW Fiksuota kaina plius PVM
29 750 €
- Vieta:
- Heilbronner Str. 22, 01189 Dresden, Deutschland

Skambinti
Pasiūlymo informacija
- Skelbimo ID:
- A21283042
- Nuorodos numeris:
- LW43630
- Atnaujinimas:
- paskutinį kartą atnaujinta 20.02.2026
aprašymas
Perkin Elmer Instruments Differential Scanning Calorimeter with Cooling, DSC 8000, N5340524
Model: DSC8000
Type: N5340524
Condition: Used
General Information:
Double-furnace differential scanning calorimeter with power compensation, Perkin Elmer DSC 8000 with Intracooler 2, enables precise heat flow measurements from approx. –70 °C to 750 °C, featuring high sensitivity and rapid thermal response.
General Instrument Specifications
DSC Type: Double-furnace design (independent sample and reference furnaces)
Measurement Principle: Power compensation
Furnace Material: 90% platinum alloy
Temperature Sensors: Distributed platinum resistance thermometers
Temperature Performance
Standard Temperature Range: approx. –180 °C to 750 °C (with appropriate cooling accessories)
With Intracooler 2: approx. –70 °C to 750 °C
Minimum Temperature (Intracooler 2): approx. –80 °C
Heating Rate: 0.01 to 300 °C/min
Cooling Rate: 0.01 to 150 °C/min
Measurement Performance
Dynamic Range: ±800 mW (typical)
High sensitivity and rapid response due to low-mass furnace design
Excellent baseline stability and temperature accuracy
Gas and Atmosphere Control
Two controlled gas lines with automatic switching
Typical purge gases: Nitrogen, Helium, Argon
Supports high gas purity (up to 99.999%)
Interfaces and Connections
USB Ethernet (LAN)
Gas inlet ports
Connection for cooling unit
Power supply connection
Accessory interfaces (e.g., autosampler, high-pressure cell, UV/photocalorimeter module)
Interface for temperature calibration
Technical Data
3.15 AMP T (5 x 20 mm) 250 V
100–240 VAC 50/60 Hz
Maximum power 400 VA
Accessories
Cooling system PolyScience Intracooler 2
Norgren gas pressure regulator with gauges for external gas supply
Cedpfx Aaoyluicehopw
96-position autosampler
High-pressure DSC cells, UV/photocalorimeter accessories
IEC power connector
Documentation
PolyScience Intracooler 2
Model: N5341746
P10N9E402E
Voltage: 240 IP-100
Hz/A/Ph: 50/7.5/1
Refrigerant: 350 g R-404A
Note regarding item condition:
Sold without software/PC.
Skelbimas buvo automatiškai išverstas. Galimos vertimo klaidos.
Model: DSC8000
Type: N5340524
Condition: Used
General Information:
Double-furnace differential scanning calorimeter with power compensation, Perkin Elmer DSC 8000 with Intracooler 2, enables precise heat flow measurements from approx. –70 °C to 750 °C, featuring high sensitivity and rapid thermal response.
General Instrument Specifications
DSC Type: Double-furnace design (independent sample and reference furnaces)
Measurement Principle: Power compensation
Furnace Material: 90% platinum alloy
Temperature Sensors: Distributed platinum resistance thermometers
Temperature Performance
Standard Temperature Range: approx. –180 °C to 750 °C (with appropriate cooling accessories)
With Intracooler 2: approx. –70 °C to 750 °C
Minimum Temperature (Intracooler 2): approx. –80 °C
Heating Rate: 0.01 to 300 °C/min
Cooling Rate: 0.01 to 150 °C/min
Measurement Performance
Dynamic Range: ±800 mW (typical)
High sensitivity and rapid response due to low-mass furnace design
Excellent baseline stability and temperature accuracy
Gas and Atmosphere Control
Two controlled gas lines with automatic switching
Typical purge gases: Nitrogen, Helium, Argon
Supports high gas purity (up to 99.999%)
Interfaces and Connections
USB Ethernet (LAN)
Gas inlet ports
Connection for cooling unit
Power supply connection
Accessory interfaces (e.g., autosampler, high-pressure cell, UV/photocalorimeter module)
Interface for temperature calibration
Technical Data
3.15 AMP T (5 x 20 mm) 250 V
100–240 VAC 50/60 Hz
Maximum power 400 VA
Accessories
Cooling system PolyScience Intracooler 2
Norgren gas pressure regulator with gauges for external gas supply
Cedpfx Aaoyluicehopw
96-position autosampler
High-pressure DSC cells, UV/photocalorimeter accessories
IEC power connector
Documentation
PolyScience Intracooler 2
Model: N5341746
P10N9E402E
Voltage: 240 IP-100
Hz/A/Ph: 50/7.5/1
Refrigerant: 350 g R-404A
Note regarding item condition:
Sold without software/PC.
Skelbimas buvo automatiškai išverstas. Galimos vertimo klaidos.
Tiekėjas
Pastaba: Užsiregistruokite nemokamai arba prisijunkite, kad gautumėte visą informaciją.
Registruotas nuo: 2014
Siųsti užklausą
Telefonas & Faksas
+49 351 8... skelbimai
Jūsų skelbimas sėkmingai pašalintas
Įvyko klaida




























