Temperatūrinio šoko bandymų kameraespec
TSD-100
Temperatūrinio šoko bandymų kamera
espec
TSD-100
Būklė
Naudotas
Vieta
Borken 

Rodyti nuotraukas
Rodyti žemėlapį
Duomenys apie mašiną
- Mašinos pavadinimas:
- Temperatūrinio šoko bandymų kamera
- Gamintojas:
- espec
- modelis:
- TSD-100
- Būklė:
- naudotas
Kaina ir vieta
- Vieta:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Skambinti
Pasiūlymo informacija
- Skelbimo ID:
- A20452790
- Nuorodos numeris:
- 24295
- Atnaujinimas:
- paskutinį kartą atnaujinta 25.02.2026
aprašymas
Espec
Model: TSD-100
100-liter usable chamber for larger test specimens up to 30 kg.
Compliant with all common international standards.
Water-cooled
Temperature range hot chamber: +60 °C to +200 °C
Temperature range cold chamber: -70 °C to 0 °C
Test chamber dimensions: 710 x 345 x 410 mm (W x H x D)
External dimensions: 1100 x 1885 x 1965 mm (W x H x D)
Water-cooled refrigeration unit
Program control via touch panel
Automatic defrost
Over-temperature protection
Operating hours counter
Mobile design
2 stainless steel specimen baskets
Cable entry Ø 100 mm
Refrigerants: 3 kg R404A, 1 kg R23
Power supply: 400V 3Ph 50Hz
Max. Power consumption: 32A
Condition: used
Weight: 1100 kg
Important information for your peace of mind as a buyer!
The following points are carried out in advance on all chambers we offer:
1. Functional inspection and replacement of necessary components
2. New filling with legally compliant refrigerants if required
3. Leak test with certificate
4. After successful inspection, each chamber undergoes a documented test run.
Condition: used
Scope of delivery: (see photo)
(Specifications and technical data subject to alterations and errors!)
Fsdpfx Absxugq Aobjpd
For further questions, please do not hesitate to contact us by phone.
Skelbimas buvo automatiškai išverstas. Galimos vertimo klaidos.
Model: TSD-100
100-liter usable chamber for larger test specimens up to 30 kg.
Compliant with all common international standards.
Water-cooled
Temperature range hot chamber: +60 °C to +200 °C
Temperature range cold chamber: -70 °C to 0 °C
Test chamber dimensions: 710 x 345 x 410 mm (W x H x D)
External dimensions: 1100 x 1885 x 1965 mm (W x H x D)
Water-cooled refrigeration unit
Program control via touch panel
Automatic defrost
Over-temperature protection
Operating hours counter
Mobile design
2 stainless steel specimen baskets
Cable entry Ø 100 mm
Refrigerants: 3 kg R404A, 1 kg R23
Power supply: 400V 3Ph 50Hz
Max. Power consumption: 32A
Condition: used
Weight: 1100 kg
Important information for your peace of mind as a buyer!
The following points are carried out in advance on all chambers we offer:
1. Functional inspection and replacement of necessary components
2. New filling with legally compliant refrigerants if required
3. Leak test with certificate
4. After successful inspection, each chamber undergoes a documented test run.
Condition: used
Scope of delivery: (see photo)
(Specifications and technical data subject to alterations and errors!)
Fsdpfx Absxugq Aobjpd
For further questions, please do not hesitate to contact us by phone.
Skelbimas buvo automatiškai išverstas. Galimos vertimo klaidos.
Siųsti užklausą
Telefonas & Faksas
+49 2861 ... skelbimai
Šie skelbimai taip pat gali jus sudominti.
Mažas skelbimas
Borken
1 181 km
Temperatūrinio šoko bandymo kamera
EspecTSD-100
EspecTSD-100
Mažas skelbimas
Vokietija
1 181 km
Druskos purškimo kamera Korozijos kamera
KöhlerHKT 500 WTG
KöhlerHKT 500 WTG
Mažas skelbimas
Borken
1 181 km
Temperatūrinio šoko bandymo kamera
EspecTSD-100 -70 °C bis +200 °C
EspecTSD-100 -70 °C bis +200 °C
Mažas skelbimas
Borken
1 181 km
Drebinimo sistema su stiprintuvu
LDSV895-440 HBT900C + SPA50K
LDSV895-440 HBT900C + SPA50K
Mažas skelbimas
Borken
1 181 km
Klimato kamera -75°C / +180°C esant drėgmei
TIRATCC 7120
TIRATCC 7120
Mažas skelbimas
Borken
1 181 km
Klimato kamera
DycometalCCK -40/1500 T 1500 Liter
DycometalCCK -40/1500 T 1500 Liter
Mažas skelbimas
Borken
1 181 km
Klimatinio bandymo kamera, 5500 litrų (5,5 m³)
CTSCW-60/5,5 -60°C bis +100°C
CTSCW-60/5,5 -60°C bis +100°C
Jūsų skelbimas sėkmingai pašalintas
Įvyko klaida