CTS
Type: T-30/950 Ex/I
CTS Temperature Test Chamber, Explosion-Proof
Control System: 32-bit Controller
LCD Control Panel
Digital display of set and actual values
Numerical input of setpoints
Plain text fault messages
Interface: RS 232
Free switching channels for user-specific test item control
Iajdpfezd Rzwox Alreu
Temperature Testing:
Temperature range: -30°C to +80°C
Temperature deviation: ±0.3 K over time
Temperature change rate:
- Heating: 2 K/min
- Cooling: 1.5 K/min down to -10°C
Radiant heat output: approx. 1000 W at +20°C, approx. 200 W at -25°C
Nitrogen inertization with residual oxygen monitoring:
The test chamber is first purged with a high volume of N2 until the
oxygen content is below 3%. It then switches to a base level supply (approx. 10% of the full purge rate).
Base level nitrogen flow is measured, displayed by a flowmeter, and monitored via a limit switch.
O2 monitoring continuously extracts gas from the test chamber through a flame arrester, directing it to an O2 sensor which checks the residual oxygen content. The gas is then returned to the chamber through a second flame arrester. The exhaust pump is monitored by a volume flow meter. Further details are available in the Dräger manual in the appendix.
The gas system is currently deactivated!
Technical data is based on an ambient temperature of +25°C, nominal voltage 400V, without test item, without radiant load, and without additional equipment.
Dimensions:
Test volume: 950 liters
Test chamber dimensions: approx. 700 mm (H) / approx. 900 mm (W) / approx. 1500 mm (D)
External dimensions: approx. 2400 mm (H) / approx. 1270 mm (W) / approx. 3125 mm (D)
Operating Data:
Electrical connection: 400V +6/-10%, 3/N, 50 Hz
Nominal power: 21.6 kW
Nominal current: 36.5 A
Protection class: IP 54
Condensate drain: non-pressurized, 1/2" internal thread
Sound pressure level: < 62 dB(A)
(measured per DIN EN ISO 3744 at 1m distance from the front)
Weight: approx. 1500 kg, control cabinet approx. 300 kg
External refrigeration unit
Refrigerant: R404A / R23
Important Safety Information for Buyers:
The following steps are carried out in advance on chambers we offer:
1. Functional testing and replacement of necessary components
2. Recharging with legally compliant refrigerant if necessary
3. Leak test with certification
4. After successful inspection, chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Subject to changes and errors in technical data. All information provided without guarantee!)
If you have further questions, we are happy to assist you by phone.
Skelbimas buvo automatiškai išverstas. Galimos vertimo klaidos.
Type: T-30/950 Ex/I
CTS Temperature Test Chamber, Explosion-Proof
Control System: 32-bit Controller
LCD Control Panel
Digital display of set and actual values
Numerical input of setpoints
Plain text fault messages
Interface: RS 232
Free switching channels for user-specific test item control
Iajdpfezd Rzwox Alreu
Temperature Testing:
Temperature range: -30°C to +80°C
Temperature deviation: ±0.3 K over time
Temperature change rate:
- Heating: 2 K/min
- Cooling: 1.5 K/min down to -10°C
Radiant heat output: approx. 1000 W at +20°C, approx. 200 W at -25°C
Nitrogen inertization with residual oxygen monitoring:
The test chamber is first purged with a high volume of N2 until the
oxygen content is below 3%. It then switches to a base level supply (approx. 10% of the full purge rate).
Base level nitrogen flow is measured, displayed by a flowmeter, and monitored via a limit switch.
O2 monitoring continuously extracts gas from the test chamber through a flame arrester, directing it to an O2 sensor which checks the residual oxygen content. The gas is then returned to the chamber through a second flame arrester. The exhaust pump is monitored by a volume flow meter. Further details are available in the Dräger manual in the appendix.
The gas system is currently deactivated!
Technical data is based on an ambient temperature of +25°C, nominal voltage 400V, without test item, without radiant load, and without additional equipment.
Dimensions:
Test volume: 950 liters
Test chamber dimensions: approx. 700 mm (H) / approx. 900 mm (W) / approx. 1500 mm (D)
External dimensions: approx. 2400 mm (H) / approx. 1270 mm (W) / approx. 3125 mm (D)
Operating Data:
Electrical connection: 400V +6/-10%, 3/N, 50 Hz
Nominal power: 21.6 kW
Nominal current: 36.5 A
Protection class: IP 54
Condensate drain: non-pressurized, 1/2" internal thread
Sound pressure level: < 62 dB(A)
(measured per DIN EN ISO 3744 at 1m distance from the front)
Weight: approx. 1500 kg, control cabinet approx. 300 kg
External refrigeration unit
Refrigerant: R404A / R23
Important Safety Information for Buyers:
The following steps are carried out in advance on chambers we offer:
1. Functional testing and replacement of necessary components
2. Recharging with legally compliant refrigerant if necessary
3. Leak test with certification
4. After successful inspection, chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Subject to changes and errors in technical data. All information provided without guarantee!)