Karštas: +50°C / +200°C Šaltas: -80°C / +100°CCTS Temperaturschock-Prüfschrank
TSS-70/130 130 Liter
Karštas: +50°C / +200°C Šaltas: -80°C / +100°C
CTS Temperaturschock-Prüfschrank
TSS-70/130 130 Liter
Būklė
Naudotas
Vieta
Borken 

Duomenys apie mašiną
- Mašinos pavadinimas:
- Karštas: +50°C / +200°C Šaltas: -80°C / +100°C
- Gamintojas:
- CTS Temperaturschock-Prüfschrank
- modelis:
- TSS-70/130 130 Liter
- Būklė:
- labai geros būklės (naudotas)
Kaina ir vieta
- Vieta:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Skambinti
Pasiūlymo informacija
- Skelbimo ID:
- A21799033
- Nuorodos numeris:
- 25161
- Atnaujinimas:
- paskutinį kartą atnaujinta 27.04.2026
aprašymas
CTS
Type: TSS-70/130
Water-cooled refrigeration unit
For sale is a high-quality temperature shock test chamber from CTS (Clima Temperatur Systeme), model TSS-70/130.
The device is used to carry out temperature shock tests and is typically utilized in industry, research, and quality assurance sectors.
Application areas:
- Material testing
- Aging tests
- Electronics and component testing
- Temperature shock and thermal cycling tests
Technical Data:
Type: TSS-70/130
Test chamber volume: 130 liters
Temperature range:
- Hot chamber: +50°C to +200°C
- Cold chamber: -80°C to +100°C
Heating rate: approx. 6 K/min from ambient to +180°C
Cooling rate: approx. 4 K/min from ambient to -60°C
Temperature deviation:
- ±1 K over time
- ±2 K spatially
Temperature change speed:
- Max. 100 K/min mean for shock test cycles (without heat radiation)
Changeover speed:
- ≤ 15 min between -65°C and +200°C (with 10 kg ICs)
Changeover time:
< 10 seconds
Electrical Data:
Connection: 400 V, 3/N, 50 Hz
Nominal power: approx. 17.2 kW
Rated current: approx. 29 A
On-site fuse: 32 A slow
Connection: Cekon 32
Refrigeration System:
Refrigerant: R404A / R23
Water-cooled, low noise, fully hermetic
Equipment / Features:
- CTS control panel
- Microprocessor-controlled regulation and monitoring system
- Program operation (up to 100 test programs possible)
- Digital setpoint and actual value display
- RS232 interface
- 2 free switching channels for external test item control
- Fault signal on potential-free contact
Load capacity up to 30 V DC, 2 A
EMC tested
Technical Design:
- Hot and cold chambers
- Transfer basket with spindle drive
- Test chamber / transfer basket made of stainless steel, material no. 1.4301
- Insert rack made of stainless steel wire
- Tubing port NW 50 with sealing plug
- Compressed air connection 1/4" male thread
- Condensate drain, non-pressurized R 1/2" female thread
- Safety door locking mechanism
- Lockable door with window
Dimensions according to installation diagram:
External dimensions approx.: 2335 x 940 x 1820 mm
Intake dimensions approx.: 1990 x 940 x 1652 mm
Chamber dimensions: Height approx. 410 mm, Width approx. 480 mm, Depth approx. 660 mm
Window: 300 x 300 mm
Further Data:
Protection class: IP 22
Sound pressure level: < 60 dB(A)
Weight: approx. 950 kg
Average power consumption per test cycle: approx. 8 kWh
Important safety information for buyers:
The following measures are carried out on all chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certification
Njdey Hkd Hepfx Af Hjlf
4. After successful checks, the chambers undergo a documented test run.
Condition: used
Scope of delivery: see images
(Specifications subject to change and error)
For further questions, please feel free to contact us by phone.
Skelbimas buvo automatiškai išverstas. Galimos vertimo klaidos.
Type: TSS-70/130
Water-cooled refrigeration unit
For sale is a high-quality temperature shock test chamber from CTS (Clima Temperatur Systeme), model TSS-70/130.
The device is used to carry out temperature shock tests and is typically utilized in industry, research, and quality assurance sectors.
Application areas:
- Material testing
- Aging tests
- Electronics and component testing
- Temperature shock and thermal cycling tests
Technical Data:
Type: TSS-70/130
Test chamber volume: 130 liters
Temperature range:
- Hot chamber: +50°C to +200°C
- Cold chamber: -80°C to +100°C
Heating rate: approx. 6 K/min from ambient to +180°C
Cooling rate: approx. 4 K/min from ambient to -60°C
Temperature deviation:
- ±1 K over time
- ±2 K spatially
Temperature change speed:
- Max. 100 K/min mean for shock test cycles (without heat radiation)
Changeover speed:
- ≤ 15 min between -65°C and +200°C (with 10 kg ICs)
Changeover time:
< 10 seconds
Electrical Data:
Connection: 400 V, 3/N, 50 Hz
Nominal power: approx. 17.2 kW
Rated current: approx. 29 A
On-site fuse: 32 A slow
Connection: Cekon 32
Refrigeration System:
Refrigerant: R404A / R23
Water-cooled, low noise, fully hermetic
Equipment / Features:
- CTS control panel
- Microprocessor-controlled regulation and monitoring system
- Program operation (up to 100 test programs possible)
- Digital setpoint and actual value display
- RS232 interface
- 2 free switching channels for external test item control
- Fault signal on potential-free contact
Load capacity up to 30 V DC, 2 A
EMC tested
Technical Design:
- Hot and cold chambers
- Transfer basket with spindle drive
- Test chamber / transfer basket made of stainless steel, material no. 1.4301
- Insert rack made of stainless steel wire
- Tubing port NW 50 with sealing plug
- Compressed air connection 1/4" male thread
- Condensate drain, non-pressurized R 1/2" female thread
- Safety door locking mechanism
- Lockable door with window
Dimensions according to installation diagram:
External dimensions approx.: 2335 x 940 x 1820 mm
Intake dimensions approx.: 1990 x 940 x 1652 mm
Chamber dimensions: Height approx. 410 mm, Width approx. 480 mm, Depth approx. 660 mm
Window: 300 x 300 mm
Further Data:
Protection class: IP 22
Sound pressure level: < 60 dB(A)
Weight: approx. 950 kg
Average power consumption per test cycle: approx. 8 kWh
Important safety information for buyers:
The following measures are carried out on all chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certification
Njdey Hkd Hepfx Af Hjlf
4. After successful checks, the chambers undergo a documented test run.
Condition: used
Scope of delivery: see images
(Specifications subject to change and error)
For further questions, please feel free to contact us by phone.