aprašymas
Binder
Model: MKFT 720 E3.2
Climate Test Chamber, Air-Cooled
Temperature range: -70°C to +180°C
Humidity range: 10% r.h. to 98% r.h.
The MKFT climate test chamber is an environmentally-simulation chamber specifically designed for industrial material testing and environmental simulation. It offers an unparalleled level of performance, far exceeding the capabilities of standard heat chambers. The unit is suitable for all tasks required in material testing, as well as aging and stress tests.
Technical Data:
External Dimensions:
Dusdpfx Asyr Hi Ujffsp
Width: 1615 mm Height: 2005 mm Depth: 1230 mm
Internal Dimensions:
Width: 1200 mm Height: 1020 mm Depth: 600 mm
Interior Volume: 734 liters
Net Weight (empty): 635 kg
Maximum Total Load: 160 kg
Maximum Load per Shelf: 40 kg
Performance Data – Temperature:
Temperature Range: -70°C to 180°C
Temporal Temperature Deviation: 0.1...0.5 ± K
Spatial Temperature Deviation: 0.3...2.0 ± K
Average Heating Rate (IEC 60068-3-5): 4.8 K/ min
Average Cooling Rate (IEC 60068-3-5): 4.0 K/min
Max. Heat Compensation: 5000 W
Performance Data – Climate:
Temperature Range: +10 to +95°C
Humidity Range: 10 to 98% r.h.
Temporal Temperature Deviation (dependent on setpoint): 0.1...1.0 ± K
Max. Heat Compensation: 800 W
Electrical Data:
Rated Voltage: 400V 3N~ ±10% 50Hz
Rated Power: 13 kW 22.2 A
Refrigerants: R-404A / R-23
Important Information for Your Safety as a Buyer!
The following work is carried out on all chambers offered by us prior to sale:
1. Functional check and replacement of necessary components
2. Refilled with regulation-compliant refrigerant if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see pictures)
(Technical data subject to change and errors excepted!)
Please don’t hesitate to contact us by phone for any further questions.
Skelbimas buvo automatiškai išverstas. Galimos vertimo klaidos.
Model: MKFT 720 E3.2
Climate Test Chamber, Air-Cooled
Temperature range: -70°C to +180°C
Humidity range: 10% r.h. to 98% r.h.
The MKFT climate test chamber is an environmentally-simulation chamber specifically designed for industrial material testing and environmental simulation. It offers an unparalleled level of performance, far exceeding the capabilities of standard heat chambers. The unit is suitable for all tasks required in material testing, as well as aging and stress tests.
Technical Data:
External Dimensions:
Dusdpfx Asyr Hi Ujffsp
Width: 1615 mm Height: 2005 mm Depth: 1230 mm
Internal Dimensions:
Width: 1200 mm Height: 1020 mm Depth: 600 mm
Interior Volume: 734 liters
Net Weight (empty): 635 kg
Maximum Total Load: 160 kg
Maximum Load per Shelf: 40 kg
Performance Data – Temperature:
Temperature Range: -70°C to 180°C
Temporal Temperature Deviation: 0.1...0.5 ± K
Spatial Temperature Deviation: 0.3...2.0 ± K
Average Heating Rate (IEC 60068-3-5): 4.8 K/ min
Average Cooling Rate (IEC 60068-3-5): 4.0 K/min
Max. Heat Compensation: 5000 W
Performance Data – Climate:
Temperature Range: +10 to +95°C
Humidity Range: 10 to 98% r.h.
Temporal Temperature Deviation (dependent on setpoint): 0.1...1.0 ± K
Max. Heat Compensation: 800 W
Electrical Data:
Rated Voltage: 400V 3N~ ±10% 50Hz
Rated Power: 13 kW 22.2 A
Refrigerants: R-404A / R-23
Important Information for Your Safety as a Buyer!
The following work is carried out on all chambers offered by us prior to sale:
1. Functional check and replacement of necessary components
2. Refilled with regulation-compliant refrigerant if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see pictures)
(Technical data subject to change and errors excepted!)
Please don’t hesitate to contact us by phone for any further questions.
Skelbimas buvo automatiškai išverstas. Galimos vertimo klaidos.
Siųsti užklausą
Telefonas & Faksas
+49 2861 ... skelbimai
Jūsų skelbimas sėkmingai pašalintas
Įvyko klaida