Profesionali bronchoskopo plovimo mašinaBHT
INNOVA E3
Profesionali bronchoskopo plovimo mašina
BHT
INNOVA E3
Pradinė kaina neįskaitant PVM
6 640 €
Gamybos metai
2013
Sąlyga
Naudotas
Vieta
Borken 

Rodyti vaizdus
Rodyti žemėlapį
Duomenys apie mašiną
- Įrenginio aprašas:
- Profesionali bronchoskopo plovimo mašina
- Gamintojas:
- BHT
- Modelis:
- INNOVA E3
- Gamybos metai:
- 2013
- Sąlyga:
- geras (naudotas)
Kaina ir vieta
Pradinė kaina neįskaitant PVM
6 640 €
- Vieta:
- Dunkerstrasse 29, 46325 Borken/Burlo, DE
Skambinti
Pasiūlymo informacija
- Sąrašo ID:
- A7725170
- Nuorodos Nr.:
- 25755
- Naujinta paskutinį kartą:
- Data 2025.08.06
Aprašymas
BHT INNOVA E3 Professional Bronchoscope Washer-Disinfector
INNOVA – Professional endoscope washer-disinfector for surgeries and small clinics
The INNOVA™ E3s is BHT’s best-selling endoscope washer-disinfector worldwide. This compact model offers a high capacity for endoscopes or bronchoscopes. Depending on the reprocessing routine, a total of 10 to 20 endoscope cycles per day are possible. This makes it the ideal solution for private practitioners and small clinics who prioritize safety, efficiency, and reliability in hygiene.
Reliability and top cleanliness with every cycle:
- Complies with DIN EN ISO 15883-1/-4 as well as RKI guidelines, and features numerous extra functions, e.g., thermal self-disinfection at 90°C in accordance with DIN EN ISO 15883-4, 4.8.1.
- Flexible: Can be combined with an additional INNOVA® E2 or E3 to achieve 30 to 40 cycles per day.
- Compatible with glutaraldehyde and peracetic acid from a range of suppliers.
- Suitable for standard endoscopes from Fuji, Olympus, Pentax, Storz, Wolf.
- Single-channel connection or patented pressure chamber option.
Fgjdpsin Edwjfx Acueh
- Option for thermal reprocessing of instruments, e.g., multiple biopsy forceps, polypectomy snares, etc.
- Thermal disinfection of final rinse water as recommended by RKI with DH version.
- Secure documentation and full traceability with batch control; user and endoscope identification via barcode scanner.
- Data output via printer, data logger, or IT interface; easy integration into existing IT systems.
Number of endoscopes: Up to 2 endoscopes or 4 ENT scopes
Hygiene concept: Hygienic workflow, single-door design
Channel connection system: Single-channel connection or patented pressure chamber system possible
Single channel control (CMS): No
Chemicals — Glutaraldehyde / Peracetic Acid: Both options available: DH Version (with boiler, for glutaraldehyde) or DC (filtration, for glutaraldehyde or peracetic acid)
Documentation and integration: Yes, printer/data logger interface standard. Printer included.
Optional: barcode scanner/IT interface
Thermal reprocessing of instruments at 90°C: Possible with additional equipment
Electrical installation: 3-phase 400 V / 50 Hz AC+N+PE. Power rating: 11 kW. Fuse: 3 x 20 A
Year of manufacture: 19.01.2013
Item condition: Used
Find more items – new and used – in our shop!
International shipping costs on request!
Skelbimas verčiamas automatiškai, todėl jame gali būtų vertimo klaidų.
INNOVA – Professional endoscope washer-disinfector for surgeries and small clinics
The INNOVA™ E3s is BHT’s best-selling endoscope washer-disinfector worldwide. This compact model offers a high capacity for endoscopes or bronchoscopes. Depending on the reprocessing routine, a total of 10 to 20 endoscope cycles per day are possible. This makes it the ideal solution for private practitioners and small clinics who prioritize safety, efficiency, and reliability in hygiene.
Reliability and top cleanliness with every cycle:
- Complies with DIN EN ISO 15883-1/-4 as well as RKI guidelines, and features numerous extra functions, e.g., thermal self-disinfection at 90°C in accordance with DIN EN ISO 15883-4, 4.8.1.
- Flexible: Can be combined with an additional INNOVA® E2 or E3 to achieve 30 to 40 cycles per day.
- Compatible with glutaraldehyde and peracetic acid from a range of suppliers.
- Suitable for standard endoscopes from Fuji, Olympus, Pentax, Storz, Wolf.
- Single-channel connection or patented pressure chamber option.
Fgjdpsin Edwjfx Acueh
- Option for thermal reprocessing of instruments, e.g., multiple biopsy forceps, polypectomy snares, etc.
- Thermal disinfection of final rinse water as recommended by RKI with DH version.
- Secure documentation and full traceability with batch control; user and endoscope identification via barcode scanner.
- Data output via printer, data logger, or IT interface; easy integration into existing IT systems.
Number of endoscopes: Up to 2 endoscopes or 4 ENT scopes
Hygiene concept: Hygienic workflow, single-door design
Channel connection system: Single-channel connection or patented pressure chamber system possible
Single channel control (CMS): No
Chemicals — Glutaraldehyde / Peracetic Acid: Both options available: DH Version (with boiler, for glutaraldehyde) or DC (filtration, for glutaraldehyde or peracetic acid)
Documentation and integration: Yes, printer/data logger interface standard. Printer included.
Optional: barcode scanner/IT interface
Thermal reprocessing of instruments at 90°C: Possible with additional equipment
Electrical installation: 3-phase 400 V / 50 Hz AC+N+PE. Power rating: 11 kW. Fuse: 3 x 20 A
Year of manufacture: 19.01.2013
Item condition: Used
Find more items – new and used – in our shop!
International shipping costs on request!
Skelbimas verčiamas automatiškai, todėl jame gali būtų vertimo klaidų.
Tiekėjas
Pastaba: Užsiregistruokite nemokamai arba prisijunkite, kad gautumėte visą informaciją.
Pateikti užklausą
Telefonas & Faksas
+49 2862 ... skelbimai
Jūsų skelbimas sėkmingai pašalintas
Įvyko klaida