6 grandinių temperatūros valdymo blokasAutotherm
AWF 130-27/VK/6K
6 grandinių temperatūros valdymo blokas
Autotherm
AWF 130-27/VK/6K
fiksuota kaina neįskaitant PVM
80 000 €
Sąlyga
Naudotas
Vieta
Borken 

Rodyti vaizdus
Rodyti žemėlapį
Duomenys apie mašiną
- Įrenginio aprašas:
- 6 grandinių temperatūros valdymo blokas
- Gamintojas:
- Autotherm
- Modelis:
- AWF 130-27/VK/6K
- Sąlyga:
- labai geros būklės (naudotas)
Kaina ir vieta
fiksuota kaina neįskaitant PVM
80 000 €
- Vieta:
- Einsteinstraße 8a, 46325 Borken, DE
Skambinti
Pasiūlymo informacija
- Sąrašo ID:
- A8776937
- Nuorodos Nr.:
- 23415
- Naujinta paskutinį kartą:
- Data 2024.11.15
Aprašymas
Autotherm
We are offering you a 6-circuit temperature control unit.
No active chiller included!
According to the attached technical brief:
Temperature range: -40°C … +85°C (extended range -40°C…+130°C)
Increased heating capacity: 27 kW instead of 18 kW
Includes 1x temperature control in the main circuit
Includes 6x temperature measurement in each supply line
Includes 6x temperature measurement in each return line
Includes 6x flow and pressure monitoring in each supply line
Includes 6x flow and pressure control
1 l/min … 12 l/min and 0.1 bar … 3 bar
Including strip control
Including frequency-controlled main circuit pump
Including 6x 3-way valve
Includes 6x additional adjustable bypass valves (2 … 12 bar), preset to 2.4 bar
Includes filling and draining device for all circuits at once
Including 50 l integrated tank
Including pneumatic drain function
Including S7 controller
Energy saving and increased cooling capacity:
An additional glycol circuit integrated into the temperature circuit provides cooling for the consumer in a temperature range from +85°C to +30°C. The absorbed energy is transferred to the on-site < 20°C chilled water network. At a supply temperature of +20°C, the cooling capacity is 50 kW.
This improves cooling speed for this temperature range and reduces energy consumption due to shorter compressor running times.
(The footprint of the basic system increases by approx. 0.3 m² as per the data sheet)
Mounted in Rittal bayed control cabinet:
2x TS8 800x1000x2000 mm
1x additional, lockable control cabinet min. 600x600x2000 mm (for control system/electrics)
Supplied via on-site or optional cooling medium supply
Supply temperature, on-site cooling brine -43°C, cooling brine demand 7.5 m³/h continuously regulated
A cooling medium must be connected for cooling performance!
Djdpfxskn Nils Af Hewc
Weight: approx. 1200 kg
Type: Autotherm temperature control unit AWF 130-27/VK/6K
Sale ex location!
Condition: used
Scope of delivery: (see picture)
(Specifications and information subject to change and error!)
Further questions can be answered by phone.
Skelbimas verčiamas automatiškai, todėl jame gali būtų vertimo klaidų.
We are offering you a 6-circuit temperature control unit.
No active chiller included!
According to the attached technical brief:
Temperature range: -40°C … +85°C (extended range -40°C…+130°C)
Increased heating capacity: 27 kW instead of 18 kW
Includes 1x temperature control in the main circuit
Includes 6x temperature measurement in each supply line
Includes 6x temperature measurement in each return line
Includes 6x flow and pressure monitoring in each supply line
Includes 6x flow and pressure control
1 l/min … 12 l/min and 0.1 bar … 3 bar
Including strip control
Including frequency-controlled main circuit pump
Including 6x 3-way valve
Includes 6x additional adjustable bypass valves (2 … 12 bar), preset to 2.4 bar
Includes filling and draining device for all circuits at once
Including 50 l integrated tank
Including pneumatic drain function
Including S7 controller
Energy saving and increased cooling capacity:
An additional glycol circuit integrated into the temperature circuit provides cooling for the consumer in a temperature range from +85°C to +30°C. The absorbed energy is transferred to the on-site < 20°C chilled water network. At a supply temperature of +20°C, the cooling capacity is 50 kW.
This improves cooling speed for this temperature range and reduces energy consumption due to shorter compressor running times.
(The footprint of the basic system increases by approx. 0.3 m² as per the data sheet)
Mounted in Rittal bayed control cabinet:
2x TS8 800x1000x2000 mm
1x additional, lockable control cabinet min. 600x600x2000 mm (for control system/electrics)
Supplied via on-site or optional cooling medium supply
Supply temperature, on-site cooling brine -43°C, cooling brine demand 7.5 m³/h continuously regulated
A cooling medium must be connected for cooling performance!
Djdpfxskn Nils Af Hewc
Weight: approx. 1200 kg
Type: Autotherm temperature control unit AWF 130-27/VK/6K
Sale ex location!
Condition: used
Scope of delivery: (see picture)
(Specifications and information subject to change and error!)
Further questions can be answered by phone.
Skelbimas verčiamas automatiškai, todėl jame gali būtų vertimo klaidų.